04

HI-LINE LV Fan Convector

7.0  Water Connections

l

Connect unit to system flow and return pipes using the two
15mm isolating valves (see fig. 3).

l

Ensure system is flushed in accordance with recognized best
practice and a suitable inhibitor is added to the system as
necessary.

l

Open valves fully, check pipe connections for leaks and vent
the heat exchanger - see Commissioning Procedure.

//

//

//

//

///

///

///

///////

/////////

//////

//////////

///////////////////////////

/////

/////

Fig. 3

5.0  Preparation

Before proceeding with the installation, unpack the carton 
contents and check against the checklist below:  

1.

HI-LINE LV unit.

2.

15mm isolating valves (1 pair).

3.

Instruction manual.

4.

Warranty card.

5.

Fixing kit (rubber mounts, cable gland and equipotential bond
pipe clamp).

6.

Transformer.

6.0  Fixing

l

Using the fixing dimensions below (see fig. 2), mark the fixing
hole positions on the wall. 

l

Drill and plug the wall for No. 8 x 40mm round head wood
screws ensuring that the wall plugs are suitable for the wall
type.

l

Remove the backing from the self-adhesive washers and place
on screws with adhesive side towards the point. 

l

Tighten the screws into the wall leaving about 9mm 
projecting. 

l

Press adhesive washers to the wall.

Remove the outer casing as follows:

l

Remove the 2 screws from the underside of the unit (see fig. 2).

l

Lift off the outer case.

l

Fit chassis on to mounting screws and tighten.

Note: 

Before proceeding with pipe-work connections check that

the unit is level. If the right hand end is lower than the left then
the ability to vent the unit may be restricted.

When water connections and electrical connections have been
completed and the unit has been vented, fit the outer cover and
secure with fixing screws.

///

///

///

//

//

//

//

//

Fig. 2

xxxxxx HiLine LV manual_Layout 1  27/06/2011  09:39  Page 5

Содержание 7-4

Страница 1: ...perating Maintenance and After Sales Manual Product Serial Number Please leave this manual with the end user heatingthroughinnovation HI LINE LV Fan Convector Model 7 4 01 02 2010 ISSUE 3 Part Number 1370058 Issue 3 ...

Страница 2: ...it Selection Sizing 03 4 0 Location 03 5 0 Preparation 04 6 0 Fixing 04 7 0 Water Connections 04 8 0 Electrical Connection 05 9 0 Commissioning Procedure 05 10 0 Technical Data 06 11 0 Operating Instructions 06 12 0 Troubleshooting 06 13 0 Maintenance 07 Contents ...

Страница 3: ... heating system For optimum fan convector heating performance the system must be capable of providing sufficient hot water through the heat exchanger This means that 1 The minimum pipe size from boiler to fan convector must be at least 15mm 2 This unit is not suitable for use on microbore pipe work 3 Where the unit is fitted on to a system with other emitters a separate circuit for the fan convect...

Страница 4: ...ing dimensions below see fig 2 mark the fixing hole positions on the wall l Drill and plug the wall for No 8 x 40mm round head wood screws ensuring that the wall plugs are suitable for the wall type l Remove the backing from the self adhesive washers and place on screws with adhesive side towards the point l Tighten the screws into the wall leaving about 9mm projecting l Press adhesive washers to ...

Страница 5: ...ong mains cord l A fused electrical spur with a maximum 3A fuse and a switch having 3mm separation on all poles must be provided in an easily accessible position The fused spur must not be positioned in a bathroom or other similar high humidity installations l For bathroom installations this unit must be connected to an equipotential bond using the pipe clamp provided in the accessories pack Attac...

Страница 6: ...ted to a high setting Set fan speed control to position I The unit will now run on low fan speed The low speed setting is recommended for normal operation with the high speed for boost heating position II when required Low Limit Operation A low limit thermostat fitted to the HI LINE LV will ensure that the fan stops after the heating system is switched off and the water flow stops If left in an op...

Страница 7: ...ermostat Poor water flow Heating Mode poor heating performance and or unit cycles on low limit thermostat Possible Causes Boiler thermostat set too low Lack of flow to fan convector Pump set on low setting Isolating valves not fully open System incorrectly balanced with unit starved of hot water flow Pipe sizing to unit too small Problem Poor heating performance Unit incorrectly sized for heat los...

Страница 8: ...t Yorkshire HU9 5PE T 01482 713927 F 01482 789056 service convectors myson co uk Spare parts and technical help on all Convector products are available from MYSON Service MYSON Eastern Avenue Team Valley Gateshead Tyne Wear NE11 0PG UK T 0845 402 3434 F 0191 491 7568 sales myson co uk www myson co uk ...

Отзывы: