EN
14
MY2238, MY2239, MY2240, MY2241 - User manual
SETTING THE LIGHTING SYSTEM
(ONLY FOR SENSOR MODELS)
(1) TEST MODE
• Turn on the wall switch. The floodlight will turn on.
• Walk through the detection area. The led floodlight turns on when you move and turns
off when you stop. Wait for the floodli- ght to turn off before moving again to test the
sensor.
• Adjust the motion sensor to cover the desired detection area. For a smaller coverage
area, point the sensor down; for a larger coverage area, point the sensor up.
(2) TIME ADJUSTMENT
The TIME adjustment controls how long the led floodlight will stay
on after the motion has been detected.
Turn the TIME control knob clockwise to increase (up to about 1 minute) how long the
floodlights stay on or anti-clockwise to decrease (down to about
5
seconds) the time
delay (fig. 6).
APROX. 5 SECONDS
APROX. 1 MINUTE
Fig. 6
(3) SENSIVITY ADJUSTMENT
The LITE adjustment determines at what light level the lighting system will start operating
when you set the sensor to Automatic Operation.
Provisionally turn the SENSIVITY control knob to the edge clockwise at the moon (dusk)
position (fig. 7). In this provisional setting mode, the motion sensor remains inactive
during daylight. At dusk when you find it is the LUX level desired for operation, simply set
the control knob to the position that the lighting system will become active as daylight
declines.
Fig. 7
ABOUT. 1000 LUX
ABOUT. 5 LUX