Operating Systems and Drivers
Manual No. 775031
19
Installing the Mylex Disk Array Controller into an Existing
Windows NT 4.x System
If Windows NT 4.x is already installed and you wish to add a Mylex Disk
Array Controller later, the controller will be a secondary (non-bootable)
controller. After installing the controller hardware and configuring a disk
array, follow the procedure below to add the necessary controller drivers.
1. Make sure Windows NT 4.x is up and running.
2. Click Start, and select Settings->Control Panel within the Start menu.
3. From the Control Panel window, double-click the SCSI Adapters icon.
4. In the SCSI Adapters box, click the Drivers tab to bring the Drivers
page to the foreground.
5. With the Drivers page in the foreground, click Add.
6. The Creating driver list progress bar is displayed briefly, and then the
Install Driver box is displayed.
7. In the Install Driver box, click Have Disk.
8. Insert the NT/NW drivers diskette into the floppy disk drive.
9. From the Install From Disk box, change the path to A:\NT and click
OK.
10. From the Install Driver box, be sure the Mylex Disk Array Controller is
selected and click OK.
11. If there is an existing Mylex driver in the system you will see a
Windows NT Setup box. Click New to install the new driver from the
diskette.
12. Again, be sure the path is A:\NT and click Continue.
The driver is copied from the diskette. The System Settings Change
box is displayed.
13. Click No at this time, because you will need to install the Mylex
Accelerated Driver before restarting Windows NT 4.x.
14. With the Drivers page in the foreground, click Add.
Содержание eXtremeRAID
Страница 1: ...eXtremeRAID Quick Installation Guide eXtremeRAID 1100 PCI to Ultra2 SCSI RAID Controller P N 775031 00...
Страница 2: ......
Страница 27: ......
Страница 29: ...Register fm Page vii Wednesday March 24 1999 1 49 PM...
Страница 30: ...Register fm Page viii Wednesday March 24 1999 1 49 PM...