Installation
Manual No. 775051
2-13
SCSI Termination
Each end of a SCSI bus must be terminated to maintain proper voltage levels
for SCSI control and data signals. The device used for this purpose is called
a terminator. Termination devices can be built into a controller, a SCSI
device, or attached to the end of a SCSI bus.
The AcceleRAID 352 controller is equipped with automatic SCSI bus
termination circuitry. If the controller is at the end of a SCSI bus, it
automatically enables on-board termination. The controller can also detect
whether single-ended (SE) or low-voltage differential (LVD) termination is
required, and can automatically configure the appropriate termination type.
The end of the SCSI bus farthest from the controller must be terminated if
SCSI devices are connected to the SCSI channel. See Figure 2-10 for an
example of a SCSI device configuration connected to the internal SCSI
channel.
☛
Note
When connecting SCSI devices, it is better to
terminate the ends of the SCSI bus itself, rather than
to terminate the end devices on the bus. This allows
hot swap devices to be added or removed from the
SCSI bus without affecting termination.
Содержание AcceleRAID 352
Страница 1: ......
Страница 2: ......
Страница 10: ...viii AcceleRAID 352 Installation Guide...
Страница 16: ...User supplied Items 1 6 AcceleRAID 352 Installation Guide...
Страница 40: ...In Case of Problems 3 6 AcceleRAID 352 Installation Guide...
Страница 46: ...BBM Specifications A 6 AcceleRAID 352 Installation Guide...
Страница 52: ...System Reboot or Power Down C 4 AcceleRAID 352 Installation Guide...
Страница 64: ...Underwriters Laboratories Statement and Warning F 6 AcceleRAID 352 Installation Guide...
Страница 88: ......
Страница 91: ......
Страница 92: ......