MyGate Q60A/R Скачать руководство пользователя страница 4

 Terminal block 2a

 Terminal block 2b

Key switch

Blinker

MAX 20 W

 Terminal block 2a

 Terminal block 2b

1

START

3

PERMANENT START 
COMMAND WITH TIMER

2

PEDESTRIAN START

Safety

emergency button

 Terminal block

 2a

 Terminal block

 2b

Link terminals 2-8

 Terminal block

 2a

 Terminal block

 2b

4

EMERGENCY STOP BUTTON   

N.B.: 

Link terminals 

2

 and 

8

 if, an emergency

 

STOP

 button is NOT USED.

WIRING SCHEME FOR THE  Q60A NEW CONTROL UNIT

 Terminal block 2b

START Pedestrian

 Terminal block 2a

 Terminal block 2b

Clock

5

MOTORS CONNECTIONS

ONE MOTOR ONLY (RIGHT) CONNECTION

ONE MOTOR ONLY (LEFT) CONNECTION 

7

8

9

10

12

13

14

15

16

17

18

7

8

9

10

12

13

14

15

16

17

18

First opening leaf, 

LEFT

M1

M2

sx

dx

MyHook

First opening leaf, 

RIGHT

First opening leaf, 

LEFT

7

8

9

10

12

13

14

15

16

17

18

7

8

9

10

12

13

14

15

16

17

18

M2 sx

M1 sx

M1 dx

M2 dx

7

8

9

10

12

13

14

15

16

17

18

M1 sx

M2 dx

M1 dx

M1 sx

M2

M1

sx

dx

M1

M2

sx

dx

BROWN

BROWN

BROWN

BROWN

BROWN

BROWN

BROWN

BROWN

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

BLACK

YELLOW / GREEN

YELLOW / GREEN

YELLOW / GREEN

YELLOW / GREEN

YELLOW / GREEN

YELLOW / GREEN

YELLOW / GREEN

YELLOW / GREEN

BLUE 

OR 

GREY

BLUE 

OR 

GREY

BLUE 

OR 

GREY

BLUE 

OR 

GREY

BLUE 

BLUE 

BLUE 

BLUE 

BLUE 

 OR 

GREY

 OR 

GREY

 OR 

GREY

 OR 

GREY

 OR 

GREY

INSIDE

INSIDE

INSIDE

INSIDE

 Terminal block 3

 Terminal block 3

 Terminal block 3

 Terminal block 3

 Terminal block 3

 Terminal block 3

 Terminal block 3

7

8

9

10

11

12

START

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

1

2

3

4

7

8

9

10

11

12

MyAster

First opening leaf, 

RIGHT

M2

M1

sx

dx

Com.

Com.

13

16

14

17

15

18

M1

M2

7

8

9

10

12

13

14

15

16

17

18

M2 sx

M1 dx

CAPACITOR

CAPACITOR

Open

Open

Closing

Closing

BROWN

BROWN

BLACK

BLACK

YELLOW / GREEN

YELLOW / GREEN

BLUE 

OR 

GREY

Содержание Q60A/R

Страница 1: ...d 2B wait few seconds and then power the unit again The fuse will be automatically restored Find and remove the short circuit cause before plugging the terminal blocks in 06_gb_utility_2020 A B lower level menu button C button to increase or change to yes si D button to decrease or change to no F1 230V fuse 5A F2 2 1 6 A F3 1 1 6 A F4 24V fuse self restorable 1 6A F5 24V fuse self restorable 0 65A...

Страница 2: ...has completely finished the control unit automatically Press buttonA steps thru the top menu until the display shows exits from the sequential programming process and all the working times have Press button B steps thru the sub menu until the display shows been saved Wait until the display shows the currents setting for example Press button C twice until the display shows Press button B repeatedly...

Страница 3: ...ot been removed In closing phase Stops and changes direction when the obstacle has been removed If you also want to connect the safety rubber edges you must connect in series their contacts with the photocell ones If temporarily the photocell contacts are not used link terminal 4 with terminal 9 4 9 Input for safety rubber edges in opening phase for swing gate Normally closed NC In opening phase S...

Страница 4: ...9 10 12 13 14 15 16 17 18 M1 sx M2 dx M1 dx M1 sx M2 M1 sx dx M1 M2 sx dx BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN BLUE OR GREY BLUE OR GREY BLUE OR GREY BLUE OR GREY BLUE BLUE BLUE BLUE BLUE OR GREY OR GREY OR GREY OR GREY OR GREY INSIDE IN...

Страница 5: ...inal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW ...

Страница 6: ...sed in the opening phase 4 and 9 if the photocells PHOTOCELLS CONNECTIONS 8 Power supply PHOTO RX 9 Power supply PHOTO TX 10 Power supply COM PHOTO TX RX 3 8 Photocells connection PHOTOCELLS CONNECTIONS 8 Power supply PHOTO RX 9 Power supply PHOTO TX 10 Power supply COM PHOTO TX RX 4 8 Photocells connection Terminal block 2a Terminal block 2b Terminal block 2a Terminal block 2b 12V dc 12V dc 24V c...

Отзывы: