Q81S

Q81S

PROTECO S.r.l.

   

Via Neive, 77 - 12050 Castagnito (CN) ITALY     Tel. +39 0173 210111 - Fax +39 0173 210199      [email protected] - www.proteco.net

CONTROL PANEL FOR 

SLIDING GATES

Control panel for 230V ac sliding gates operators 

Automatic programming mode with obstacle detection

Sequential programming mode: adjustable force, slow down, working time per single motor

Immediate closing

Pedestrian opening

Multi-occupation feature

Second radio channel interface (optional)

Output for electrolock connection

Hammer action and lock pulse function

Built-in radio receiver 433,92 MHz (32 codes) suitable for fixed or rolling code transmitters

Input for 8K2 resistive safety edge

Self diagnosis of malfunctions by LED coding

230V ac

TECHNICAL FEATURES

Instructions Manual 

Item code 

PQ81S

Pcb’s dimensions 

137 x 84 x 37 mm

Pcb’s weight 

160 g

Main power supply 

230V, 50-60Hz

Power supply tolerance 

-10%  +20%

Transformer 

230/21Vac – 15VA 

Main fuse 

5 A

Rated power 

600 W

Max. power draw 

3,5 A

Power draw in stand-by  

30 mA

Blinker 

24Vac, max 20 W

Accessories 

24Vdc , max 5 W

Accessories 

-20  +50   °C

Protection rating  

IP55

Содержание PQ81S

Страница 1: ...nnel interface optional Output for electrolock connection Hammer action and lock pulse function Built in radio receiver 433 92 MHz 32 codes suitable for fixed or rolling code transmitters Input for 8K2 resistive safety edge Self diagnosis of malfunctions by LED coding 230Vac TECHNICAL FEATURES Instructions Manual Item code PQ81S Pcb s dimensions 137 x 84 x 37 mm Pcb s weight 160 g Main power suppl...

Страница 2: ...ive safety edge in CLOSING pag 11 3 7 4 8K2 resistive safety edge in OPENING 3 8 FLASHING LIGHT pag 10 3 9 HOV TO PLUG THE 2 RADIO CHANNEL JACK pag 10 3 9 1 Auxiliary radio channel AUX 3 9 2 Signalling light 3 9 3 CCourtesy light 4 DEFAULT SETTINGS pag 11 5 BROWSING THE MENU 5 1 FUNCTIONS MENU 5 1 1 Automatic closing 5 1 2 8K2 RESISTIVE SAFETY EDGE INPUT cut the power off 6 OPERATION MODE pag 12 7...

Страница 3: ...a supervisor or unless they get properly aware of potential hazards associated Always cut the power off before operating Make sure the earth connection is duly wired Wiring installation and functional tests must be carried out by expert qualified per sonnel in full compliance with current regulation EN12453 Use of this control panel must be restricted to the transformer supplied by the Ma nufactur...

Страница 4: ...ettable fuse 24V 1 6A FR2 self resettable fuse 24V 0 6A V1 varistor secondary K1 K3 motor relé K4 flashing light relé TR2 filter JP1 GREEN TERMINAL aerial connection JP2 Secondary MOLEX card 24V ac JP3 Primary MOLEX card 230V ac JP4 BLUE TERMINAL command devices JP5 RED TERMINAL line and photocells JP6 YELLOW TERMINAL flashing light JP7 BLACK TERMINAL limit switch JP8 ORANGE TERMINAL motor JP9 GRE...

Страница 5: ... 0173 210199 info proteco net www proteco net PHASE NEUTRAL EARTH CLOSE CAPACITOR FLASHING LIGTH 24V ac MAX 20w PEDESTRIAN STOP START NEUTRAL CLOSING PHOTOCELLS OPENING PHOTOCELLS PHOTOCELLS IN CLOSING PHOTOCELLS IN OPENING 24V RX 24V TX RX TRANSFORMER 230V 21V RED RED BLACK BLACK WIRING Diagram for 230Vac OPERATORS 24V TX 3 ELECTRICAL CONNECTIONS CIRCUIT BREAKER OPEN NEUTRAL NEUTRAL FC CLOSING FC...

Страница 6: ...RAL JP5 RED TERMINAL line and photocells 5 photocell in closing N C contact 6 photocell in opening N C contact 7 RX photocells 24V 8 TX RX 24V 9 TX photocells 24V JP6 YELLOW TERMINAL flashing light 10 flashing light 24V ac max 20W 11 flashing light 24V ac max 20W JP7 BLACK TERMINAL LIMIT SWITCH 12 neutral 13 limit switch in closing 14 limit switch in opening JP8 ORANGE TERMINAL MOTOR 15 OPEN 16 NE...

Страница 7: ...matically No connections are needed JP8 Brown Whit 3 1 MOTORS wiring Please check motor wirings according to the gate opening direction Gate opening from left to RIGHT viw from inside courtyard FC OPEN NEUTRAL FC CLOSING Gate opening from right to LEFT view from isnide property The control unit is pre set for gate opening from left to right looking from inside the courtyard as shown in the drawing...

Страница 8: ... START N O contact to 3 4 terminal JP4 An additional PEDESTRIAN START contact can be wired in PARALLEL N O contact OROLOGIO 3 3 2 KEY SWITCH Wire the KEY SWITCH N O contact to 1 4 terminal JP4 3 2 MAIN POWER The main line must be protected by a proper CIRCUIT BREAKER Connect the line 230V to 18 19 20 terminal JP9 fulfilling the polarity 18 PHASE 19 EARTH 20 NEUTRAL CIRCUIT BREAKER PHASE NEUTRAL PE...

Страница 9: ...nd objects N B To desable the photocell in closing during installation plug 5 and 9 together 3 6 2 Photocells in OPENING Feed the photocells through 7 8 9 terminal JP5 Wire the photocell contact N C contact to 6 7 terminal JP5 An additional photocell set can be wired in SERIES N C contact If the photocell beam is broken during OPENING the gate stops and reverses for 3 sec The PHOTOCELLS IN OPENING...

Страница 10: ...fety edge and the N C contact of the photocell in series If the contact is broken during CLOSING the gate stops and reverses If the contact is broken during OPENING the gate keeps on working normally 3 7 2 Mechanical safety edge in OPENING Wire the safety edge to 6 9 terminal JP5 If the contact is broken during OPENING he gate stops and reverses after 3 sec If the contact is broken during CLOSING ...

Страница 11: ...3 7 4 8K2 RESISTIVE SAFETY EDGE IN OPENING cut the power off before proceeding ATTENTION Wire the 8K2 safety edge to 6 9 terminal JP5 Press SET SET TX together and feed the control panel If the contact is broken during OPENING the gate stops and reverses for 3 sec If the contact is broken during CLOSING the gate keeps on working normally 8K2 SAFETY EDGE PHOTOCELLS IN OPENING cut the power off befo...

Страница 12: ...TIVATES or DESACTIVATES every time you press the remote control If you wish to choose this function mode select the switches as follows 1 OFF 2 ON 3 OFF 4 NO EFFECT TIMED COMMANDA The contact ACTIVATES when giving a start command by the remote control and stays for 90 seconds If you wish to choose this function mode select the switches as follows 1 ON 2 ON 3 OFF 4 NO EFFECT 3 9 2 Signalling LIGHT ...

Страница 13: ... Press BREAK and release The blinker and led DL1 light up the control panel starts the count down Press BREAK again when reached the desired time the blinker turns off The time has been set automatic closing time max 120 sec To desactivate the AUTOMATIC CLOSING Press SET for 3 sec and release the led DL1 blinks Press BREAK and hold for 5 sec the AUTOMATIC CLOSING has been deactivated 5 1 2 8K2 RES...

Страница 14: ...off before setting the switches SWITCH SW1 dip n 1 This function gives priority to the first open command The control unit won t accept additional START commands during OPENING and AUTOMATIC CLOSING COUNT DOWN dip n 2 dip n 3 dip n 4 OFF MULTI OCCUPATION mode DEACTIVATED ON MULTI OCCUPATION mode ACTIVATED OFF Soft start mode DEACTIVATED At opening motors work at the set thrust POWERO ON Soft start...

Страница 15: ...CO S r l Via Neive 77 12050 Castagnito CN ITALY Tel 39 0173 210111 Fax 39 0173 210199 info proteco net www proteco net SWITCH SW2 dip n 1 dip n 2 dip n 3 dip n 4 ON OFF Motor positioned on the RIGHT Default ON Motor positioned on the LEFT OFF ON OFF Standard slow down Default ON Soft slow down ACTIVATED OFF ON OFF Mantained action DEACTIVATED Default ON Maintained action ACTIVATED OFF ON OFF N C c...

Страница 16: ... of reset Before starting proceed to delete all existing radio codes 7 1 DELETING EXISTING RADIO CODES Press SET TX and keep pressed for 10 seconds DL1 blinks DL1 turns off All codes have been deleted 7 2 LOADING A REMOTE CONTROL AS START COMMAND Press SET TX once DL1 blinks 1 blink stop 1 blink Load within 5 sec the remote control you wish to store The control panel has stored the radio code and ...

Страница 17: ...g programming the gates stop before reaching the ground endstops turn SENS sensitivity clockwise to Press SET and keep pressed for 10 sec DL1 starts blinking When motor starts working release SET Motor runs firstly a FULL OPENING till reaching the limit switch in opening Then it starts CLOSING till reaching the closing limit switch When the procedure is finished all time settings are saved The con...

Страница 18: ... mechanical ground endstops are fitted in Opening and Closing SENS in maximum position to Programming can be carried out both with the remote control or WORK button Press TEST for 3 sec DL1 starts blinking release Press the button of the remote control previously loaded The gate STARTS OPENING At 80 of opening press the remote control to start SLOW DOWN till reaching the opening limit switch Now o...

Страница 19: ... Check the connection to the power supply 230V Check the operation of the ACCESSORIES wired to the START N O contact see section 3 3 Check the wiring otherwise deactivate the input Check the wiring diagram see section 3 5 Check the photocell alignment Check and remove the obstacle Check the wiring diagram Check the power connection Disable the photocell input see section 3 6 Check the connection N...

Страница 20: ...n 1 motor 230V Models S Accessories MRX01 Is built to be integrated into a machine or to be assembled with other machinery to crate a machine under provisions of 2006 42 EC Machinery Direc ve It complies with the essen al requirements of EEC Direc ves 20 5 EC ow Voltage Direc ve 20 4 0 EC Electromagne c Compa bility Direc ve 2014 53 Radio Telecommunica ons Terminal Equipments Direc ve The manufact...

Отзывы: