S33 Sump Pump

INSTRUCTIONS AND SERVICE MANUAL

AUTOMATIC

S33A1 & S33A1C

VERTICAL 

FLOAT SWITCH 

S33V1 & S33V1C

AUTOMATIC

S33P1 & S33PC-1

(CONTROL WITH SERIES PLUG)

NOT SHOWN

R

Содержание MYERS S33

Страница 1: ...23833A587 Bag 18812A108 S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL AUTOMATIC S33A1 S33A1C VERTICAL FLOAT SWITCH S33V1 S33V1C AUTOMATIC S33P1 S33PC 1 CONTROL WITH SERIES PLUG NOT SHOWN R ...

Страница 2: ...dy in direction of flow AIR LOCKING A sump pump is said to be air locked if water traps air in the pump and it cannot get out thus preventing pump from operating All Myers sump pumps have a small air vent hole in the impeller chamber to let out trapped air If this hole becomes plugged pump may air lock This usually happens on pumps that are used mainly in the wet seasons In summer months the pump ...

Страница 3: ...debris or sediment WARNING Sump basin must be vented in accordance with local plumbing codes Myers sump pumps are not designed for and CANNOT be installed in locations classified as hazardous in the National Electric Code ANSI NFPA 70 7 The sump basin should be between 14 and 18 in diameter for the S33A1 S33P 1 S33A1C S33PC 1 S33M1C and 12 18 for the S33V1 S33V1C S33PV1 made of plastic fiberglass ...

Страница 4: ...e quality Myers parts Tools Needed for All Pump Installation Pipe wrench slot screwdriver hacksaw round file drill 1 8 drill bit pvc cement Cement a 15 piece of PVC pipe to adapter Use appropriate diameter piping Drill a 1 8 relief hole in the pipe 5 above pump connection This hole prevents pump from air locking Clamp Check Valve to top of 15 PVC pipe with water flow arrow pointing away from pump ...

Страница 5: ...s of position When level rises in the sump the cylinder floats up with the level When the cylinder position is at an angle of about 45º the steel ball rolls over a detent and actuates the switch This starts the pump motor As the sump level draws down the cylinder floats down and when it is again at an angle of about 45º the steel ball drops away deactivating the switch and the motor stops BE SURE ...

Страница 6: ...sing the series cord plug the two plugs may not be plugged tight together Float may be stuck Be sure float operates freely in basin If all symptoms check OK motor winding may be open Take to service center for check Check valve may be installed backward Arrow on valve points in direction of flow Discharge shut off valve if used may be closed Pump may be air locked Start and stop several times by p...

Страница 7: ...nder this Warranty must be returned to MYERS in Ashland Ohio or such other places MYERS may designate freight prepaid PRODUCT IMPROVEMENTS MYERS reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for units sold and or shipped prior to such change or improvement WARRANTY EXCLUSIONS MYERS SPECIFICALLY DISCLAIMS...