Myenergi harvi Скачать руководство пользователя страница 2

 

myenergi

 Pioneer Business Park, Faraday Way 

      Revision 4.2 June 2022 

Stallingborough, Lincolnshire, England, DN41 8FF 

D3171 

Introduction 

harvi 

is a clever little device that enables 

myenergi 

devices

 

to be installed without using a 

directly connected current transformer (CT) for measuring the grid and/or generation power 

- instead the CT is connected to 

harvi

. No power source is needed for 

harvi

 - the energy 

harvested from the CT is used to transmit the measurement   signal to your other 

myenergi 

device. This means batteries or separate power supply  are eliminated.  

 
 
 
 
 
 
 
 
 
Step 1:

 

Installation  

 

Before you start… 

 

harvi

 can be wall mounted  

 

harvi

 can have up to 3 CT’s connected 

 

Multiple harvi devices can be used on one site 

 

Batteries or power supply NOT required 

 

1.

 

Ensure the CT is securely clipped around the  cable to be monitored - make sure the 
arrow sticker on the CT is pointing in the direction of normal    current flow (normally 
towards the consumer unit).  

2.

 

There is a cable grip installed on the back of the 

harvi

. Simply pass the CT wire 

through the top hole and then push down to lock into place. 

NOTE 

It is not G100 compliant to connect the grid CT to a 

harvi 

in conjunction with a 

zappi 

 

 

Serial          

Number 

Pair                               

Button  

12345678                         

harvi-

65A3PR 

Status            

LED 

Содержание harvi

Страница 1: ... Pioneer Business Park Faraday Way Revision 4 2 June 2022 Stallingborough Lincolnshire England DN41 8FF D3171 harvi Installation Guide Model Number harvi 65A3PR harvi 65A3PR A energy harvesting wireless sensor ...

Страница 2: ... or separate power supply are eliminated Step 1 Installation Before you start harvi can be wall mounted harvi can have up to 3 CT s connected Multiple harvi devices can be used on one site Batteries or power supply NOT required 1 Ensure the CT is securely clipped around the cable to be monitored make sure the arrow sticker on the CT is pointing in the direction of normal current flow normally towa...

Страница 3: ...D should flash blue once indicating that harvi is on channel 1 However there may be times when the channel may need to changed see Optional Changing Channel 3 Then the LED will flash red to indicate the harvi is in pairing mode 4 First check the myenergi device you are pairing harvi to is set as Master 5 Then select Settings Advanced enter passcode Linked Devices Pairing Mode 6 The harvi should ap...

Страница 4: ... configured to use the harvi The function of the CT s connected to the harvi are also configured via the myenergi unit 1 On the myenergi Master device go to Settings Advanced CT config 2 Disable the relevant CT input s for that device this ensures the unit uses the harvi CT instead of a wired CT 3 Then go to Advanced Settings Linked Devices Devices 4 Highlight the harvi device and press or 5 Confi...

Страница 5: ...rrent Accuracy 2 0 Typical Transmission Rate 1s 1A 10s 0 5 1A 30s 0 5A Wireless Interface 868 915MHz proprietary protocol Mounting Location Indoor only can be housed in an IP rated plastic box if required for outdoor installation Dimensions 98 x 98 x 36mm Operating Temperature 30 C to 50 C Technical Support If you experience any issues with your harvi during or post installation please contact our...