full meal can you carry out the weight-loss treatment.
14. During operation, the instrument should be in full contact with the skin to avoid
uneven heating.
15. Start with the lowest energy at the beginning of operation, and gradually add
energy after adaptation.
16. When using this instrument, the operating area must be kept moist and avoid dry
skin operation.
17. After the operation, scrub the instrument with normal saline to ensure its
cleanliness and extend its service life.
18. Fixate the lapo laser pads on the customer before turning on the device. Adjust
energy from low to high level based on the customer’s feedback.
19. Apply products that contain high volume of oil to keep it moisturized.
20. Make sure the entire surface of the lipo laser pad is in full contact with the skin.
21. Lipo laser pad can be used separately on intended treatment area, then adjust the
energy level and working time. It is advised to treat for 20 min or so on each site. It
brings better result when combined with massage, RF and ultrasonic devices.
5. Troubleshooting & Solutions
1. The instrument cannot be started, and the key light on the back of the instrument
does not work.
A. Make sure the power cord is connected to a valid power socket.
B. Whether the fuse tube on the back of the instrument is loose or burnt out.
2. No RF output of the instrument?
A. Please check whether the plug connecting the instrument handle and the body is
tightly connected.
B. Please check whether the treatment area has been cleaned. Grease or oil essential
oil products may cause poor contact between the treatment handle of the instrument
and human body, resulting in no rf output.
3. Weakened RF output?
A. Please check whether the plug connecting the instrument handle and the body is
tightly connected.
B. Please check whether non-conductive grease and other substances are stained on
the treatment handle, which will cause poor contact and weaken the output.
C. Please check whether the product used is the adaptive product specified by the
instrument.
4. No suction or very little suction?
A. Please close the instrument and check the filter element specially used for the
instrument, which may need to be replaced.
B. Please check the rubber ring of the handle plug, because the rubber ring may be