handpiece on each spot of the area from the corner of the mouth to the middle of the ear; C. Fix
the handpiece on each spot of the area from the nose wing to the temple.
2) Then fix the handpiece on each spot along three lines from lower side of cheek to the upper
side.
A. fix the handpiece on each spot of the area from the lower jaw to the cheekbone B. fix the
handpiece on each spot of the area from the middle of the jawbone to the cheekbone; C. fix the
handpiece on each spot of the area from the masseter to the temple.
3) Finally, move the handpiece along three lines from the inside of cheek to the outside.A. move
the handpiece from the lower jaw to the earlobe; B. move the handpiece from the corner of the
mouth to the middle of the ear; C. move the handpiece from the nose wing to the temple.
*Note.
1. The working head needs to be firmly attached to skin during treatment;
2. the sensation of heat is obvious on cheekbone, forehead, eye area and other areas with less
fat, it is recommended that the energy be adjusted down
3. When replacing the working head, push the switch for changing working head, and then the
working head will automatically come loose, do not pull it hard.
4. After each operation, the working head should be cleaned with warm water or saline.

8. Troubleshooting

Fault type

Possible causes

Solutions

When connected to power
supply, the machine can not
be started and the buttons
can not work.

1. Something wrong with the
power supply.
2. Power cord damage or poor
contact.
3. Internal circuit failure.

Check the socket to see
whether the power supply is
normal. Or try to replace the
power cord

Working

time

indicator

flashes( once per second)

This occurs when the machine
does not sense the presence
of the working head
1. The working head has been
detached
2. Poor contact between the
handpiece

and

the

the

working head
3.The

working

head

is

damaged

Try to repeatedly detach and
insert the working head or
replace it

If there are other failures, please contact your local dealer for repair or replacement.

*Note: as instrument is precision electronic product, the use of the instrument is prohibited in a
humid environment, such as bathhouse, bath room and other humid places. If it is damaged by
water, please stop using it immediately and return it to the factory for repair!

Содержание SR-VR2012

Страница 1: ...User Manual of SR VR2012...

Страница 2: ...ct stimulates the body s own collagen renewal mechanism in which old collagen is stimulated to contract and new collagen is able to regrow Thus it can help reduce wrinkles tighten skin and reshape con...

Страница 3: ...collagen giving you healthier skin better skin texture and improved facial contours It is mainly used on the whole face for relieving sagging skin excessive wrinkles and aging rough skin texture and r...

Страница 4: ...4 Introduction of the machine...

Страница 5: ...5 Handpiece working head introduction...

Страница 6: ...ries from the box and keep the packaging for later transportation or storage Check the accessories according to the accessory list and check for any mechanical damage Steps for use 1 Clean Before trea...

Страница 7: ...the A B working modes 1 Mode A red light goes on long press the working button on the handiece there is constnt energy output Release the button the energy output stops 1 Mode B blue light goes on lo...

Страница 8: ...he neck Avoiding the area of Adam s apple is recommended Eye area Fix the handpiece on each spot of the area from the inner corner of the eye to the outer corner of the eye not recommended for the upp...

Страница 9: ...he working head push the switch for changing working head and then the working head will automatically come loose do not pull it hard 4 After each operation the working head should be cleaned with war...

Страница 10: ...nd disinfected and properly stored 6 If you do not use the instrument please turn off the power unplug the instrument and place all kinds of accessories properly 10 Machine Specifications Specificatio...

Страница 11: ...after three months significant tightening effect and skin quality improvement face firmness increased tightness in skin around the eyes obvious contour 13 Advantages over similar products 1 this prod...

Страница 12: ...15 Related Certificates...

Страница 13: ...ely related to safety issues After reading please put away this manual in a place where you can find it at any time Possibility of injury or damage to the equipment Meanings of Symbols This symbol ind...

Страница 14: ...hose with facial neurological disorders those who are drinking alcohol or taking medication those who feel severe fatigue Pregnant women those with dilated capillaries due to long term use of steroid...

Страница 15: ...n of current backflow Warning Do not use or store this instrument in bathrooms or places where there is high humidity Beware of water ingress malfunction fire or electric shock In case of water ingres...

Страница 16: ...Do not place containers containing liquid substances such as water on the main body of the instrument Beware of fire electric shock and malfunction Do not use the parts of this instrument in other in...

Страница 17: ...eatment Please perform the treatment step by step according to the results of the skin test and the level of needs of skin for treatment When the customer s skin reaches the limit of tolerance please...

Отзывы: