handpiece on each spot of the area from the corner of the mouth to the middle of the ear; C. Fix
the handpiece on each spot of the area from the nose wing to the temple.
2) Then fix the handpiece on each spot along three lines from lower side of cheek to the upper
side.
A. fix the handpiece on each spot of the area from the lower jaw to the cheekbone B. fix the
handpiece on each spot of the area from the middle of the jawbone to the cheekbone; C. fix the
handpiece on each spot of the area from the masseter to the temple.
3) Finally, move the handpiece along three lines from the inside of cheek to the outside.A. move
the handpiece from the lower jaw to the earlobe; B. move the handpiece from the corner of the
mouth to the middle of the ear; C. move the handpiece from the nose wing to the temple.
*Note.
1. The working head needs to be firmly attached to skin during treatment;
2. the sensation of heat is obvious on cheekbone, forehead, eye area and other areas with less
fat, it is recommended that the energy be adjusted down
3. When replacing the working head, push the switch for changing working head, and then the
working head will automatically come loose, do not pull it hard.
4. After each operation, the working head should be cleaned with warm water or saline.
8. Troubleshooting
Fault type
Possible causes
Solutions
When connected to power
supply, the machine can not
be started and the buttons
can not work.
1. Something wrong with the
power supply.
2. Power cord damage or poor
contact.
3. Internal circuit failure.
Check the socket to see
whether the power supply is
normal. Or try to replace the
power cord
Working
time
indicator
flashes( once per second)
This occurs when the machine
does not sense the presence
of the working head
1. The working head has been
detached
2. Poor contact between the
handpiece
and
the
the
working head
3.The
working
head
is
damaged
Try to repeatedly detach and
insert the working head or
replace it
If there are other failures, please contact your local dealer for repair or replacement.
*Note: as instrument is precision electronic product, the use of the instrument is prohibited in a
humid environment, such as bathhouse, bath room and other humid places. If it is damaged by
water, please stop using it immediately and return it to the factory for repair!