together for better beauty results.
20. Clean the instrument with normal saline after operation to ensure its cleanliness
and hygiene to prolong its service life.
21. The front side of the skin scrubber is for deep cleaning and the back side is for
lifting and nutrients introduction.
22. Screw head cleaning: basic cleaning must be done to maintain the prevention of
infection. After using the screw head, disposable toothbrush can be used to brush out
the dirty stuff in the groove of the screw head, rinse tit off with clean water, then soak
with alcohol for 3 minutes, and finally rinse the alcohol ingredients.
23. Internal cleaning (after each bottle of solution is used):
Replace the probe with a cleaning head, fill the solution bottle with half a bottle of
purified water, turn on the device, plug the probe by hand, adjust the water flow to
the maximum, and let the water flow back to clean the residual solution in the pipe.
Around a minute.
24. All parts of the instrument must be tightened, otherwise internal leakage will
reduce air pressure, resulting in no suction or too little water flow.
4. Troubleshooting & Solutions
1. The instrument can't start and the key lamp on the back of the instrument doesn't
work?
A. Ensure that the power cord is connected to a working power outlet.
B. Ensure the fuse tube on the back of the instrument is not loose or being burnt.
2. No RF output of the instrument?
A. Please check whether the plug connecting the instrument handle and the body is
tightly connected.
B. Please check whether the treatment area has been cleaned. Grease or oil essential
oil products may cause poor contact between the treatment handle of the instrument
and human body, resulting in no RF output.
3. No ultrasonic energy output?
A. Please check whether the connecting wire of the handle is well connected and
whether there is any damage.
B. If the above methods cannot address the issue, please contact the instrument
dealer for assistance.
4. No suction coming from the hydra dermabrasion and there’s no nutrients outflow?
A. Please check whether the waste water recovery bottle cap is tight or not, and
whether the nutrient solution bottle is tight or not.
B. Please check whether the button for adjusting suction and nutrient solution stays
on 0.
C. Please check whether the output of nutrient solution is excessive.