Time Adjustment (Advised operation time for each handle
is around 8-10 min)
/-(Adjust the energy level subjecting to one’s own comfort level; It
is advised to start with 2-5 at the beginning.)
Start/Stop
Mode (A/ B/ C)
Select the Mode of your choice based on one’s own comfort level. It is
advised to select B mode for the first time of use.
Mode A: It is always on, suitable for those with thick fat and needs to lose
weight.
Mode B: it is slow flashing, suitable for beginners, and consolidating the
effect.
Mode C: it is fast flashing, suitable for those with a small treatment area,
thick fat, or excess fat.
2.Dos and Dont’s
1. Please detach the probes, clean with water and store in place after each use.
2. Use a grounding pin and make sure the power socket of the device is properly
connected before each operation.
3. Ensure that the voltage of the device is appropriate. If the voltage of the local power
supply is unstable, we recommend that users increase to the matching power voltage.
4. In order to ensure the therapeutic effect and normal service life expectancy of the
device, please use the specified accessories provided or recommended by the original
manufacturer.
5. The device should not be placed in wet environment or near water, nor should they
be directly exposed to sunlight.
6. Do not place the device near a strong heat source, because this may affect the life
and normal use of the device.
7. Before treatment, please remove all metal objects from the body first, so as to avoid
unexpected conditions and influence the curative effect.
8. Please restrain from using the device on eyes, thyroid, parathyroid, testicles,
abdomen of pregnant women, and pacemakers.
9. Patients who are suffering from illness should consult with a doctor and gain
permission from the doctor before using.
10. Please turn off the power switch of the device, and ensure that the total power
supply of the device is turned off before the staff leaves after daily use, so as to ensure
the safety of the electrical products.
11. Use device or train device operators in strict accordance with instructions in the user
manual.
12. When taking other weight-loss drugs, it is recommended to stop taking them for 1 to
2 months before treatment. Extension of the course of treatment is recommended if you
wish to lose weight immediately.
13. Don't use the instrument with an empty stomach. After a full meal, wait at least 1
hour before a course of weight loss treatment.
14. When operating, the instrument should fully touch the skin to avoid uneven heat.
15. Start from the lowest energy level and slowly add up.
16. When using this device, the operating parts must be kept moist and dry skin should
be avoided.
17. Clean the instrument with normal saline after operation to ensure its cleanliness and
hygiene and prolong its service life.
18. Laser paddle can be used alone. Each operation time is around 45 min, 3-5 times
per week.
Select to go to the interface below
1.8 Detailed Operation: Small Laser Paddle
Time Adjustment (Advised operation time for each handle
is around 8-10 min)
/-(Adjust the energy level subjecting to one’s own comfort level; It
is advised to start with 2-5 at the beginning.)
Start/Stop
Mode (A/ B/ C)
Select the Mode of your choice based on one’s own comfort level. It is
advised to select B mode for the first time of use.
Mode A: It is always on, suitable for those with thick fat and needs to lose
weight.
Mode B: it is slow flashing, suitable for beginners, and consolidating the
effect.
Mode C: it is fast flashing, suitable for those with a small treatment area,
thick fat, or excess fat.
12
11
Содержание MS-54D1S