4. The instrument should not be placed in damp places or near water sources, and
should not be directly exposed to sunlight.
5. Do not place the instrument near a strong heat source, as this may affect the life
and normal use of the instrument.
6. Before treatment, please remove all metal objects from the body first, so as to
avoid unexpected conditions and influence the curative effect.
7. Please restrain from using the device on eyes, thyroid, parathyroid, testicles,
abdomen of pregnant women, and pacemakers.
8. Patients who are suffering from illness should consult with a doctor and gain
permission from the doctor before using.
9. Please turn off the power switch of the device, and ensure that the total power
supply of the device is turned off before the staff leaves after daily use, so as to
ensure the safety of the electrical products.
10. Use device or train device operators in strict accordance with instructions in the
user manual.
11. When taking other weight-loss drugs, it is recommended to stop taking them for 1
to 2 months before treatment. Extension of the course of treatment is recommended
if you wish to lose weight immediately.
12. Don't use the instrument with an empty stomach. After a full meal, wait at least 1
hour before a course of weight loss treatment.
13. When operating, the instrument should fully touch the skin to avoid uneven heat.
14. Start from the lowest energy level and slowly add up.
15. When using this device, the operating parts must be kept moist and dry skin
should be avoided.
16. Clean the instrument with normal saline (do not use ethyl alcohol) after operation
to ensure its cleanliness and hygiene and prolong its service life.
17. When operating Vacuum&RF at face, the suction should not be too high, to avoid
get red or purple marks.
18. The laser pads can be used separately, fix it on the operating area, set the energy,
each treatment takes about 20 min. It has a better effect with massage, RF and
ultrasonic device.
19. High oil content products must be applied during operation to keep moist.
20. During operation, the instrument should contact the skin fully, not only one point,
to avoid burns and uneven heat.
21. It is recommended that the continuous use of the instrument should not exceed 2
hours. When it reaches 2 hours, the instrument should be turned off and power off,
left for 10-30 minutes, and then restarted for use.
22. During operation, the operating handle should not stay on the skin for more than
3 seconds and should be moved and operated.
23. When using the laser pads, the whole surface of the laser pads should be in
contact with the skin fully, not only in a small area.
24. 40K probe cannot be used at head, chest, breasts, bones, heart and back.