10. Use device or train device operators in strict accordance with instructions in the
user manual.
11. Don't use the instrument with an empty stomach. After a full meal, wait at least 1
hour before a course of weight loss treatment.
12. When operating, the instrument should fully touch the skin to avoid uneven heat.
13. Start from the lowest energy level and slowly add up.
14. Make sure the vacuum plate is fully in contact with the skin.
15. When using this device, the operating parts must be kept moist and dry skin
should be avoided.
16. Clean the instrument with normal saline after operation to ensure its cleanliness
and hygiene and prolong its service life.
17. Make sure all metals objects are removed from the body of both the operator
and the one who’s being operated on.
18. It is advised to keep the treatment time under 30 min per treatment area each
time to avoid any discomfort of the operator wearing the bracelet.
19. During the treatment: wear bracelets on both hands. Push down on the pedal
with foot and move hands slowly once contacting with the skin.
5. Troubleshooting & Solutions
1. The instrument can't start and the key lamp on the back of the instrument doesn't
work?
A. Ensure that the power cord is connected to a working power outlet.
B. Ensure the fuse tube on the back of the instrument is not loose or being burnt.
2. No RF output of the instrument?
A. Please check whether the plug connecting the instrument handle and the body is
tightly connected.
B. Please check whether the treatment area has been cleaned. Grease or oil essential
oil products may cause poor contact between the treatment handle of the instrument
and human body, resulting in no RF output.
3. Weakened RF output?
A. Please check whether the plug connecting the instrument handle and the body is
tightly connected.
B. Please check whether non-conductive grease and other substances are stained on
the treatment handle, which will cause poor contact and weaken the output.
C. Please check whether the product used is the adaptive product specified by the
instrument.
4.The device can be activated, but the wrong information appears on the screen?
A. Please unplug the power plug behind the device and wait about 1 minute before
restarting the device.