background image

C300 Convertible Manual 

This is the Owners Manual and Calibration guide for all C300 Convertible Scales (below). The C300 uses 
the same internal program as the Palmscale 5.0. So, for advanced programming information, please 
view the Palmscale 5.0 Advanced Programming/Repair . 

Low Batteries & bad battery connections are the #1 cause of scale malfunction and inaccuracy

! We 

test all of our scale returns from consumers. Fully 60% of consumer returns are battery related 
problems. This sounds silly but it's true! A scale will perform slowly, or read inaccurately when it has low 
batteries. Please replace the batteries often (and only use good quality batteries). We include good 
quality batteries with all of our scales but batteries can run low in storage. If your scale simply won't 
turn on while on Battery power, this is often caused by loose battery connections. Battery prongs 
(terminals) are made of metal. They must be making good contact with your batteries in order for the 
scale to power on. You can use a paperclip to slightly bend the battery prongs to make them have a 
better connection. Also some poorly designed batteries have recessed or partially obstructed battery 
terminals. This may cause your prongs to be touching the plastic housing of the battery instead of the 
metal battery terminal.  

   

This scale is very easy to operate. However, there are certain caring and operation instructions you 
should read before your first use. We know taking the time to read these instructions is time consuming, 
but this scale is a precision instrument and must be handled with the utmost care.  

IMPORTANT:

  

1)

To open the scale, lift up on the cover using the notch at the front.  

2)

 There is a jewelers scoop and tweezers on the bottom of the scale. The tweezers are stored above the 

scoop. To release the jewelers scoop, slide it out towards the back of the scale. When the scoop is out of 
the scale, the tweezers can also be removed.  

3) 

Always empty the tray/platform before turning the power on (clear the platform before turning on)  

4)

 Do not get the scale wet or hot and do not operate on any wet or hot surface to clean the scale, wipe 

the surface with a clean damp cloth or mild non-abrasive cleaner. Do not use an abrasive cleaner 
because it may damage the finish.  

5)

 

Do not overload the scale.

 That is, do not place anything that weighs more than 200 Grams on the 

platform. 

You may permanently damage the load cell.

  

6) 

Handle the scale with care. This is a precision instrument and should never be dropped or otherwise 

mishandled  

7)

 Do not leave anything on the scale when not in use.  

Содержание C300 Convertible

Страница 1: ...his may cause your prongs to be touching the plastic housing of the battery instead of the metal battery terminal This scale is very easy to operate However there are certain caring and operation instructions you should read before your first use We know taking the time to read these instructions is time consuming but this scale is a precision instrument and must be handled with the utmost care IM...

Страница 2: ...t on 2 Turn the scale on by pressing After 2 seconds the display will read 0 0 g 3 Always allow the scale to warm up for at least 30 seconds before weighing for accuracy stability 4 Place the item to be weighed on the center of the silver platform and read the value on the display 5 TARE Function If you need to weigh loose items or anything in a container or tray you should 1 Turn the scale On 2 P...

Страница 3: ...e the weight from the tray If the readings are inaccurate perform calibration again If your scale will not properly calibrate or shows err please visit our website for advanced calibration troubleshooting instructions BATTERY INSTRUCTIONS Use 2 CR2032 3volt batteries Please make sure the polarity is correct when installing new batteries Slide the locking switch near the battery cover to access bat...

Страница 4: ... have changeable faceplates to suit your daily mood or personality Remember that this is a precision instrument It is essential that you never drop shake or otherwise mishandle this instrument Electronic precision scales use delicate sensors that can easily be damaged if the scale is excessively shocked dropped or overloaded Treat your scale well and it will last for many years ...

Отзывы: