AC ELWA

®

-F Assembly- and Operation Manual, 170224 

19.

 

EU Declaration of Conformity 

 my-PV GmbH, Teichstrasse 43, A-4523 Neuzeug, hereby declares that the device  
 

AC ELWA-F 

complies with the following standards and regulations: 
EN 55014-1, EN 55014-2, EN 60335-2-21, EN 60730-2-9, EN 61000-3-2, EN 61000-3-3, EN 62233 
The above mentioned company holds documentation to proof the compliance with safety 
requirements. 

 

Neuzeug, 24.2.2017  

Dr. Gerhard Rimpler, Managing Director 

 

20.

 

Technical data 

AC ELWA-F 
Mains Voltage 

200 - 250 V AC 

Heating power max.  

3,000 W at 230 VAC 

Power control  

Linear frequency curve 

Frequency range 

47 Hz to 54 Hz 

Low frequency setting 0 W 

49.000-51.900 Hz 

High frequency setting 

49.100-52.000 Hz, 0.1 Hz above low frequency setting 

Mains connector 

Single phase, earthed connector, 230 V, 50 Hz 

Line circuit breaker 

13 A or 16 A 

Power cord 

2.8 m 

Standby-consumption 

<1.4 W 

Water pressure 

max. 10 bar (1 MPa) 

Efficiency 

>99 % at nominal power 

Protection class 

IP21 

Operating temperature range 

5 ° C to 40 ° C 

Display 

3 LED’s 

Dimensions (LxWxD) 

130  x 180 x 600  mm including heating rod 

Heating rod lenght 

45 cm 

Heating rod thread 

1 ½ Inch 

Weight 

2 kg including cable, without packaging 

 
 
Subject to change. 
 
my-PV GmbH 
Teichstrasse 43, A-4523 Neuzeug 
www.my-pv.com 

Содержание AC ELWA-F

Страница 1: ...ty 3 5 Mounting and Installation Instructions 3 6 Electrical Connection 4 7 Operation with frequency shift inverters 4 8 Controls and Indicators 4 9 Operating status indicator 5 10 Factory preset 5 11...

Страница 2: ...local regulations for mounting and connection Any damage caused by ignoring the installation and user manual is not covered by the manufacturer s warranty Permanent equipotential bonding of the device...

Страница 3: ...ted section of the heating rod is 90 mm from sealing face the length of the thread pipe must not exceed 80 mm Use the O ring seal supplied Do not use any grease or lubrication agents The plastic threa...

Страница 4: ...000 W It is recommended to set maximum power of the AC ELWA F not more than half the power of the battery inverter The lowest adjustable maximum power limit of the AC ELWA F is 500 watts Corresponding...

Страница 5: ...spanner position 3 Plug in device all 3 LEDs are flashing after some seconds to indicate setup mode 4 Turn rotary knob to 13 A setting LEDs run from top to bottom 5 After 5 seconds of no knob turn LED...

Страница 6: ...der Settings Menu AC ELWA Software connects automatically with AC ELWA F Current data of the device are displayed including AC frequency 5 Choose Frequency Control in Stettings Menu 6 Choose desired s...

Страница 7: ...upply In addition to adjusting the fuse setting the AC ELWA F s maximum power can be reduced to fit to smaller battery inverters My PV recommends to set maximum power of the AC ELWA F not more than ha...

Страница 8: ...ternal electronics Device stops and reconnects after cool down 4x flash Hardware fault Unit must be serviced by authorized staff 6x flash Temperature probe fault Unit must be serviced by authorized st...

Страница 9: ...ower max 3 000 W at 230 VAC Power control Linear frequency curve Frequency range 47 Hz to 54 Hz Low frequency setting 0 W 49 000 51 900 Hz High frequency setting 49 100 52 000 Hz 0 1 Hz above low freq...

Отзывы: