Drywall dust or other fragments may be present in your fireplace’s vent space, clean this area before you install the
blower kit. Any bearing or motor damage resulting from this condition is not covered by the warranty policy.
Instructions for Design Version - GA3450TA Blower Kit
This Blower Kit is tested and safe when installed in accordance with these installation instructions. It is your re-
sponsibility to read all instructions and consult the Owner’s Installation Manual for your particular model number
for Supplemental Information before starting installation. Blower operates on 120V/60Hz power.
High Quality Aftermarket Fireplace Blowers & Fans
1-800-466-4045
Check the contents of the carton.
Make sure nothing was damaged in shipment.
Do NOT install a damaged blower kit!
Blower Kit Parts
Step 1: Turn Off Fireplace and allow it to cool down.
Disconnect from 120V Power. Shut off the Gas supply.
Remove the louver which covers the lower vent space
below the firebox.
Figure: 1
NOTE: Diagrams and Illustrations NOT to Scale
Page 1 of 4
WARNING
RISK OF FIRE AND ELECTRICAL SHOCK!
TURN OFF THE GAS AND ELECTRICAL POWER BEFORE INSTALLING BLOWER!
When installed, make sure to contain any excess wire of the cord set;
Preventing it from making contact with moving or hot objects.
Description
Qty.
Blower - with Mounting Bracket
Thermodisc / Heat Sensor
Variable Speed Control
Cord Set
Installation Instructions
(Downloadable)
1
1
1
1
1
1
Packet of 6 Screws
My Fireplace Blower LLC
Burlington, Wisconsin
1-800-466-4045
•WHITE Wire - Connects to Metal Spade on Motor
•BLACK Wire - Connects to Variable Speed Control
and Heat Sensor, then to Metal Spade on Motor
•GREEN Wire - Push onto Metal Ground tab on side
of Motor (Figure: 4)
•Lay cord set on floor and connect wires (Figure: 1).
Plug Power Cord into “Live” Outlet. Test Blower operation
by placing flame to Silver Disc of Heat Sensor for 10
seconds. Verify Speed Control and Rocker Switch are in
“ON” Position. (ON is AUTO) (Figures: 1, 7 & 9).
* You may remove the Variable Speed Control and/or
Heat Sensor if you choose not to use them.
*
*
•Push disconnects together, one plastic insulator
fits inside the other. Black and White wires can go
to either Metal Spade on Motor, does not matter
which one.
Rocker Switch
ON(Auto) / OFF
Heat Sensor /
Thermodisc
Green
White
Green
On
110/115V
Blower
Motor
Black
Off
1
OFF
White
Black
Black
White