![My Fireplace Australia Deco EC00010 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/my-fireplace-australia/deco-ec00010/deco-ec00010_operating-and-installation-instructions-manual_1861472022.webp)
22
OPERATING
&
INSTALLATION
INSTRUCTIONS
FOR
ECOMAXX
DECO
ZERO
CLEARANCE
WOOD
HEATER
The
most
common
equipment
used
are
fibreglass
rods
with
threaded
fittings
and
stiff
plastic
brushes.
The
brush
is
forced
up
and
down
inside
the
chimney
flue
to
scrub
off
the
creosote.
The
chimney
should
be
checked
regularly
for
creosote
build
‐
up.
Inspection
and
cleaning
of
the
chimney
can
be
facilitated
by
removing
the
baffle.
Do
not
expect
chemical
cleaners
to
keep
your
chimney
clean.
The
chimney
cowl
can
be
removed
for
inspection
and/or
cleaning
of
the
chimney.
The
chimney
should
be
swept
following
these
steps:
1)
Remove
the
fire
baffle
and
air
tubes.
2)
Remove
the
chimney
cowl.
3)
Sweep
the
chimney.
4)
Clean
the
inside
of
the
firebox.
5)
Re
‐
install
the
baffle,
the
air
tubes
and
the
chimney
cowl.
CAUTION:
OPERATION
OF
YOUR
ECOMAXX
DECO
WITHOUT
THE
BAFFLE
MAY
CAUSE
UNSAFE
AND
HAZARDOUS
TEMPERATURE
CONDITIONS
AND
WILL
VOID
THE
WARRANTY.
5.2.4
Fire
Baffle
Removal
Prior
to
Cleaning
the
Chimney
Before
starting
to
clean
your
chimney,
we
recommend
that
you
remove
the
fire
baffle
to
avoid
creosote
dust
collection
on
top
of
the
baffle.
Follow
the
steps
below
to
remove
the
fire
baffle:
See
Appendix
1:
Baffle
Plate
Location
for
details.
5.2.5
Chimney
Fire
Regular
chimney
maintenance
and
inspection
can
prevent
chimney
fires.
If
you
have
a
chimney
fire,
follow
these
steps:
1.
Close
the
zero
clearance
wood
inbuilt
door
and
the
air
intake
controls;
2.
Alert
your
family
of
the
possible
danger;
3.
If
you
require
assistance,
alert
your
fire
department;
4.
If
possible,
use
a
dry
chemical
fire
extinguisher,
baking
soda
or
sand
to
control
the
fire.
Do
not
use
water
as
it
may
cause
a
dangerous
steam
explosion;
5.
Check
outside
to
ensure
that
sparks
and
hot
embers
coming
out
of
the
chimney
are
not
igniting
the
roof;
6.
Do
not
use
the
zero
clearance
wood
inbuilt
again
until
your
chimney
and
zero
clearance
wood
inbuilt
have
been
inspected
by
a
qualified
chimney
sweep
or
a
Fire
Department
Inspector;