![Mx Onda MX-PG2202X Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/mx-onda/mx-pg2202x/mx-pg2202x_user-and-installation-manual_1861180039.webp)
12
ADJUSTING THE VALVES
If the pressure in the gas supply (natural gas or butane gas) differs from that
specified for the gas plate, it may happen that the flame is irregular or goes out,
in which case the adjustment of the valve would have to be regulated, to do
this, follow the following process:
1.
Turn on the cooking zone you wish to adjust and wait approximately 10 minutes for
the safety sensor to be completely hot.
2.
Turn the knob counterclockwise to the position ( ) minimum flame level.
3.
The flame must not be switched off or moved
to the burner, if it is switched off or moves
towards the burner it will be necessary to
readjust the valve.
4.
To access the valve reset screw, remove the
button corresponding to the cooking zone you
wish to adjust by pulling it upwards.
5.
Using a fine flat-blade screwdriver, readjust the
screw on the top left of the valve.
6.
Repeat steps 1 to 5 with the other cooking
zones.
Adapting to different types of gas
Appliance category:
I
2H
I
2E
I
2E+
I
2L
I
2HS
I
2ELS
I
2ELW
I
3+
I
3B/P
I
3P
I
2H3+
II
2E3B/P
I
2HS3B/P
II
2
ELWLS3B/P II
2
ELL
3
B/P
Size
of the
burner
Type
of gas
Pressure
mbar
Nozzle
diameter
Nominal charge
Reduced
charge
g/h
l/h
kW
Kcal/h
kW
Kcal/h
Semi fast
(Medium)
Natural
G20
20
0.97
-
171
1,8
1548
0,6
516
Butane
G30
30
0.67
130,8
-
1,8
1548
0,6
516
Triple ring
(Big)
Natural
G20
20
1.25
-
323
3,4
2924
1,5
1290
Butane
G30
30
0.93
247
-
3,4
2924
1,5
1290