The user can know and estimate the distance of the target from the starting point of the search, and 
to do this we change the distance level, and we choose a distance from the list of distances. For 
example, if we had chosen at the beginning of the search a search distance of 500 meters, we reduce 
the distance to 250 meters and then start the search once Others and  do the previous steps, and at 
this time . carry the device and wait for a reading. To estimate the distance of the target better, and 
then we move to the stage of locating the target location.

Trget

intersection

 

point

 

First read

User

Second Read

Third read

User

User

Start up

INSPECTOR 900-PLUS

In the case of the presence of the target for which the search was determined, the 
device will receive a reading and a signal by changing the path of the device 
automatically from the normal path on which it was stable to another path, this 
direction is the direction of the location of the target. We memorize this direction in 
theory or put a specific signal in the direction of the device’s rotation to save the 
direction, then we press the OK button again and go in a different side path for the 
first reading. In order to make sure of the correctness of the direction of the target, by 
taking more than one reading from the device from different points, we notice in 
theory that all the readings that we made are interrupted by one point, which is the 
location and point of the target.

Содержание Inspector 900-Plus

Страница 1: ...The latest Gold Metal detector Metal and Water Finder User Manual...

Страница 2: ...For user Index Technical Important Nots Main Unit Device Parts Main Unit Setup page 1 page 2 page 3 page 5 page 6 page 7 Search System page 11 Charging page 18 Notes page 19 Metal and Water Finder pa...

Страница 3: ...tage areas would limit the results and performance Don t operate two devices with same method of search at the same place The operator Must remove any metals that might affect the opreatin eg Rings wa...

Страница 4: ...and intelligent guidance system Yes through the graphical interface indicating the locations and direction of the target Detection System Long Range Locator System the system detects the energy level...

Страница 5: ...evel of 5 to 80 Device weight 1 25 KG with the case Device dimensions 19 x 12 x 5 5 cm case dimensions 40 x 33 x 17 cm INSPECTOR 900 PLUS Do not search in rainy weather Do not use headphones during lo...

Страница 6: ...connected to the sensor socket in the upper face of the device It is used with the long range search system and for point Built in radar sensor Battery charger Plugs into the charging socket on the s...

Страница 7: ...adar sensor Headphone plug 5 Connect the Grip 6 On and off button 7 8 Laser button to determine the direction of the target with high accuracy Main Unit INSPECTOR 900 PLUS Main unit 5 3 7 6 4 1 2 Lase...

Страница 8: ...key located on the left side of the device and the boot screen shown in the attached image will appear Then the device will automatically go to the main interface shown in the attached picture ENGLIS...

Страница 9: ...nguage When selecting the settings icon When selecting the search icon The main interface contains two search icons to enter the search system and start searching and settings to adjust the device set...

Страница 10: ...he OK key to choose one of the available languages English German Farsi Arabic Brightness Adjustment When selecting on the brightness icon the screen brightness value is changed by pressing the OK but...

Страница 11: ...ng the following 4 available multiple targets Gold Silver Bronze Copper By pressing the OK button in the same way both the distance parameter which reaches 1250m and the depth which reaches 25m is det...

Страница 12: ...ISTANCE DEPTH 10m 100m GOLD search Starting hz 10 When we press start search the search interface appears which contains search options Note Frequency 0 is an indicator that symbolizes the feature of...

Страница 13: ...et according to its types by sending a signal with a frequency corresponding to the the transmitted electrical signal This device relies on its detection of various types of precious metals through th...

Страница 14: ...vice where we move the device by hand to the right and then slowly left and then the hand that holds the device is fixed Then we press the OK button to calibrate the device with the type of soil Move...

Страница 15: ...User User Start up INSPECTOR 900 PLUS In the case of the presence of the target for which the search was determined the device will receive a reading and a signal by changing the path of the device a...

Страница 16: ...e and then move in a straight line towards the target until we reach a point where it exceeds the target s location and we will notice that the device has changed its direction automatically from its...

Страница 17: ...arry the device and wait for a reading of the target site if there is a reading of the target site here we know that the depth may be within 10 meters and we do this process to reduce the depth level...

Страница 18: ...r confirming the point of the target we reduce the search distance to the lowest level and maintain the depth of the search to the highest level and complete the steps of work and stand in the detecti...

Страница 19: ...g begins we remove the transmitting and receiving antennas remove the handle keep the radar sensor installed in the main unit carry the device and use it as a point verification unit where we direct t...

Страница 20: ...the device you must disconnect the charging socket INSPECTOR 900 PLUS Charging We note the conditions of the battery during work as it expresses how full the battery charge is in order from full to e...

Страница 21: ...Notes page 20 INSPECTOR 900 PLUS...

Страница 22: ...Metal and Water Finder...

Отзывы: