1  Specifications

Model

RV4000

Power

1080 W

Voltage

230 V 

Frequency

50 Hz

Diameter

270 mm

Blowing nozzle

375 x 82 mm

Maximum speed

1400 r/min

Air flow

39,6 m³/min

Dimensions (l x w x h)

520 x 450 x 540 mm

Net weight

16 kg

2  Safety

IMPORTANT!

Read and understand all informations and safety instructions carefully before using your 

ventilator.

•  Keep out of reach of children. Do not allow children to play with the device or near the device.

•  Electrical connection: Fans and ventilators are designed for operation at 230V/50Hz. Use only with a plug with 

earthing contact! Sockets used must be earthed and have to save by a fault current protection switch.

•  Never use the device with a damaged power cable. If the power cable is damaged, it must be replaced by a cable 

of the same type and dimensions.

•  Only used approved extension cables!

•  Do not drop or throw the device since this could lead to damage of components or wiring.

•  Always place the device on a steady, even surface.

•  Tie down the device during transport to prevent it from slipping and sliding.

•  The device cannot be operated in puddles or stagnant water. Do not store or operate it in open spaces. If the electric 

wiring or parts of the device get wet, dry it thoroughly before using it again.

•  Do not cover or block the air inlets and outlets.

•  Do not look into the outlet hole of the blower. Foreign objects may be dangerous.

• 

Always use the blower with safety shields fitted, to avoid contact with the rotating wheel.

•  Do not put any object or body part inside the blower.

• 

Do not use the blower in locations where chemical, inflammable or explosive substances are stored.

•  Check the blower before each use, and do not use it if damaged.

•  Disconnect the power cable before moving or cleaning the blower.

•  Do not hang the blower on a wall or ceiling.

•  This appliance may not be used by children or persons with reduced physical, sensory or mental capabilities, unless 

under supervision.

3  Use

This fan is used primarily to maintain pressure of blown games, advertising balloons and other types of air blown objects. 

The blower may be used inside and outside buildings. The blower may also be used to dry wet floors, carpets and 

upholstery and also to cause air flow inside premises.

copyrighted 

document 

- all 

rights 

reserved 

by 

FBC

Содержание 722313659

Страница 1: ...n en voor later gebruik bewaren P 05 Veuillez lire et conserver pour consultation ult rieure P 08 Please read and keep for future reference FR EN NL RV4000 722313659 Ventilator Ventilateur Ventilator...

Страница 2: ...enshuis Als de kabel of onderdelen nat worden moeten ze zorgvuldig worden gedroogd voor gebruik De luchtingang en luchtuitgang mogen niet worden afgedekt of verstopt Kijk niet in de uitlaatopening van...

Страница 3: ...eem controleren Controleer regelmatig of de voedingskabel niet beschadigd is Verwijder regelmatig de behuizing en controleer of er kale draden losse verbindingen of kleurveranderingen op de interne be...

Страница 4: ...skabel Motor of schakelaar defect Vervang de motor of de schakelaar Zwakke luchtstroom Luchtingang belemmerd Reinig de luchtingang De ventilator schakelt de zekering uit De verlengkabel is te lang Geb...

Страница 5: ...tilis dans des flaques ou de l eau stagnante Ne l utilisez pas l ext rieur Si le c ble lectrique ou des composants deviennent humides ils doivent tre soigneusement s ch s avant utilisation Les arriv e...

Страница 6: ...ag Retirez r guli rement le bo tier et v rifiez s il y a des fils d nud s des fixations desserr es et des changements de couleur sur le c blage interne Enlevez et r parez les c bles endommag s si n ce...

Страница 7: ...cez le c ble Moteur ou commutateur d fectueux Remplacez le moteur ou le commutateur Faible circulation d air Obstacles l entr e d air Nettoyez l entr e d air Le ventilateur d clenche le fusible La ral...

Страница 8: ...and sliding The device cannot be operated in puddles or stagnant water Do not store or operate it in open spaces If the electric wiring or parts of the device get wet dry it thoroughly before using i...

Страница 9: ...work Inspection of the electrical system Check the electricity cable regularly for damages Remove the housing regularly and check the internal wiring for blank conductors loose fittings and discolour...

Страница 10: ...d power cord Replace the power cord Damaged motor or switch Replace the motor or switch Slow air flow Obstructions at air inlet Clean the inlet The fan activates electric fuse The extension cord is to...

Страница 11: ...take 2 3 4 5 6 7 8 9 10 1 on off rocker switch blk on off rocker switch cap strain relief lq tight power cord nut hex front guard AC motor housing blower rubber foot screw 1 qty 1 1 1 6 12 qty 1 1 1 1...

Страница 12: ...temming van de hierboven aangeduide richtlijnen met inbegrip van deze betreffende het tijdstip van de verklaring der geldende veranderingen R pond aux normes g n rales caract ris es plus haut y compri...

Отзывы: