EN
8
M1.2.MV200PP-MV300PP-MV400PP.NLFREN 15062018
WARNING! Read the instruction manual. When this symbol appears on a product, it means
the instruction manual must be read.
ENGLISH
............................................................................................................1-7
Read The Instruction manual: When this symbol is marked on a product, it
means that the instruction manual must be read.
1
1 Description
1. Front guard
2. Hose lip
3. Handle
4. Power cord
5. Power switch
2 Specifications
Model
MV200PP
MV300PP
MV400PP
Fan size
200 mm
300 mm
400 mm
Voltage
230 V ~ 50 Hz
230 V ~ 50 Hz
230 V ~ 50 Hz
Power
250 W
750 W
700 W
Air flow
23 m³/min
56 m³/min
128 m³/min
Fan speed
2900 tpm
2750 rpm
2850 rpm
Net weight
8,5 kg
16 kg
18,5 kg
3 Safety
IMPORTANT! Read and understand all of the safety information and instructions in this
manual before operating your ventilator. Retain this manual for future reference.
•
Do not operate this ventilator where there are harmful, explosive or flammable gasses, fumes or hazardous
substances.
•
When using mains-powered appliances, basic safety precautions should always be followed to reduce the risk of fire,
electric shock and personal injury.
• Do not expose to rain or water spray. Do not submerge this ventilator in water or use in excessively wet conditions.
•
This is not a toy! Keep out of reach of children. This ventilator is intended for use by only qualified persons.
•
Risk of injury! Keep hair, loose clothing, fingers and all body part away from air inlet and outlet.
• Risk of injury! Do not move ventilator while operating.
• Risk of electric shock! Take precautions to prevent injury.
• In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied
through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off
by the utility.
• Before operating ventilator, be sure that you know how to switch it off in an emergency.
• Before operating ventilator be sure there are no items that can be blown about by airstream. The minimum distance
from the ventilator must be 1 meter.
•
Always use only the electrical power (voltage and frequency) specified on the model plate of the ventilator.
• Always use 14 AWG or better extension cord.
• Always install the ventilator so that it is not directly exposed to water spray, rain or dripping water.
• Always ensure that all cords are protected against short circuit and overload.
• Always check electric cords for damage and replace if necessary before using ventilator.
• Always disconnect ventilator from power source when not in use.
• Never pull or carry ventilator by power cord.
© 2013, Pinnacle Products International, Inc.
3
4
5
2
1
1. FRONT GUARD
2. DUCT LIP
3. HANDLE
4. POWER CORD
5. POWER SWITCH
1. ROOSTER AAN VOORZIJDE
2. AFWERKING LEIDING
3. HANDVANT
4. ELEKTRICITEITSSNOER
5. SCHAKELAAR
1. GRILLE AVANT
2. LÈVRE DE GAINE
3. POIGNÉE
4. CORDON D’ALIMENTATION
5. INTERRUPTEUR D’ALIMENTATION
2
copyrighted
document
- all
rights
reserved
by
FBC