8 to 11 

This installer supplied valve must be in the gas service line ahead of the appliance regulator in the gas stream 
and in a position accessible in the event of an emergency. 

LOCATION 

• Installation of the e

quipment should be performed by qualified, certified, and authorized personnel who are

familiar and experienced with local installation codes.

• Before Installation please read instructions completely and carefully.
• Do not remove permanently affixed labe

ls, warnings or plates from the product.

• Please observe all local and national codes and ordinances
• Installation must conform with local codes, or in the absence of local codes, the National

Fuel Gas Code, ANSI Z223.1 (latest edition).

In Canada, installation should conform to installation codes for gas burning appliances and 
equipment standard CAN/CGA-B 149.1 or the Propane installation code, CAN/CGA-B 149.2, 
as applicable. 

The appliance must be isolated from gas supply piping system, by closing its  individual manual shut off valve 
during any pressure testing of the gas supply piping system at test pressure equal to or less than ½ psi (3.45kpa) 

CLEARANCES 

The appliance area must be kept free and clear of all combustibles 
SR, SRMR Series products are for installation in Non-Combustible locations only. 

COMBUSTIBLE 

NON COMBUSTIBLE 

SIDES 

12 Inches 

0 Inches 

REAR 

8 Inches 

0 Inches 

FLOOR 

6 Inches 

0 Inches 

 AIR SUPPLY & VENTILATION 

The area in front of, around and above the appliance must be kept clear to avoid any obstruction of the flow of 
combustion and ventilation air. 

Adequate clearance must be maintained around the appliance for easy servicing. Provision should be made for 
any  commercial,  heavy-duty  cooking  appliance  exhaust  combustion  waste  products  to  the  outside  of  the 
building.  Usual  practice  is  to  place  the  appliance  under  an  exhaust  hood,  which  should  be  constructed  in 
accordance to the local codes. Strong exhaust fans in this hood or in the overall air conditioning system can 
produce a slight vacuum in the room and / or cause air drafts, either of which can interfere with the pilot or 
burner performance and could be difficult to diagnose.  

Содержание Sierra SRCM-24

Страница 1: ...SRS 24 SRS 36 SRCM 24 SRCM 36 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE 108 MIAMI FL 33181 TEL 786 600 4687 1 844 218 8477 sales mvpgroupcorp com www mvpgroupcorp com ...

Страница 2: ...installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les instructions d installation d utilisation et d entretien avant d installer ou de reparer cet équipement ...

Страница 3: ...ersion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspected prior to the carrier leaving your premises Damage must be noted in writing on the BOL and pictures must be taken at this time For any goods shipped prepaid by MVP Group Corp and the goods are damaged and or lost in transit please call the Logistics D...

Страница 4: ...n the backguard flue riser a different high shelf is required than the one supplied with the range A Range Mount Kit is required NOTE If a Salamander broiler Cheese Melter is to be mounted on range read installation instructions for Salamander broiler Cheese Melter before installing high shelf Special care must be taken to ensure that the gas supply piping and or gas pressure regulator is not expo...

Страница 5: ...e pilot and that there are no yellow flames from the burner 9 Turn the oven thermostat to off and replace the lower kick plate NOTE It may be necessary to relight the pilot several times until the lines are purged of any trapped air and a constant gas flow is attained MAINTENANCE INSTRUCTIONS CAUTION Never use ammonia in an oven that is warmer than room temperature and always have direct ventilati...

Страница 6: ...nless steel surfaces All stainless steel parts should be wiped regularly with hot soapy water during the day and a stainless steel liquid cleaner at the end of the day To remove encrusted materials soak in hot water to loosen the material and then use a wood or nylon scraper Contact the factory factory representative or a local service company to perform repairs INSTALLATION WALL SUPPORT 1 Place t...

Страница 7: ... a diameter less than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas suppli...

Страница 8: ...ts individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than psi 3 45kpa CLEARANCES The appliance area must be kept free and clear of all combustibles SR SRMR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inc...

Страница 9: ...T IS OFF TURN ON GAS SUPPLY UNIT PRODUCING CARBON DEPOSITS GAS TYPE VERIFY CORRECT GAS GAS SUPPLY PRESURE CONTACT LOCAL GAS SUPPLIER PRIMARY AIR NOT ADJUSTED PROPERLY ADJUST AIR SHUTTER ORIFICE TOO BIG VERIFY ORIFICE SIZE PILOT WILL NOT REMAIN LIT PILOT FLAME NOT ADJUSTED ADJUST PILOT FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOG...

Страница 10: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...