All Sierra appliances are adjusted and tested before leaving the factory, effectively matching them to sea level 
conditions. Adjustments and calibrations to assure proper operation may be necessary on installation to meet 
local conditions; low  gas characteristics,  to correct  possible problems caused by rough handling or vibration 
during  shipment,  and  are  to  be  performed  only  by  qualified  service  personnel.  These  adjustments  are  the 
responsibility of the customer and/or dealer and are not covered by our warranty. Before lighting any pilots, 

make sure that burner valves and thermostats are turned “off”.

 

A. TOP BURNERS / RAISED GRIDDLE

BROILER / BROILER

. All top section burners are equipped with constant

burning  pilots.  These  are  to  be  manually  lighted  immediately  after  the  gas  is  turned  on  and  the  system  is
checked  for  leaks.  Burner pilots  are  provided  for each  burner  and  can  be  rechecked  for  proper  adjustment.
Adjustments can be made with a screwdriver to
the brass pilot valve accessible through the valve cover.

B. HOT TOP / GRIDDLE.

 The pilot should be lighted immediately after the gas is turned on and the system is

checked for leaks. The pilot can be reached with a long match through the valve cover, or by lifting the plate
upward and accessing through the top.

C. STANDARD OVEN

. Pilot gas is tapped from the main burner manifold pipe, routed through tubing to a pilot

safety valve, and then to the pilot burner. Gas flow is controlled by the safety valve.
Oven pilot lighting or relighting is to be completed in the following sequence:

(1) Turn the oven thermostat knob to “off” and wait 5 minutes.
(2) Remove the oven’s lower kick plate by lifting up and out. This exposes the pilot safety valve

 and the igniter

button.
(3) Make sure any accumulated gas has dispersed. Since propane gas is heavier than air, check near the floor
area for the odor of propane gas before attempting to light any pilot burners.
(4) Depress the red button on the safety valve and hold it in throughout the lighting procedure.
(5) Press the red button of the pilot igniter, and you should hear a snap and see a spark at the pilot burner. If a
spark or spark igniter is not present apply a lit match to the pilot burner head.
(6) Continue to depress the safety valve button until the pilot remains lit when released.
(7) If pilot is extinguished, repeat step 4 through 6 above.

(8) Turn the oven thermostat knob “on” and set to desired temperature setting, watch to make sure the oven

burner ignites from the pilot and that there are no yellow flames from the burner.

(9) Turn the oven thermostat to “off” and replace the lower kick plate.

NOTE: It may be necessary to relight the pilot several times until the lines are purged of any trapped air and a 
constant gas flow is attained. 

MAINTENANCE INSTRUCTIONS 

CAUTION

:  Never  use  ammonia  in  an  oven  that  is  warmer  than  room  temperature  and  always  have  direct 

ventilation! If the appliance is on casters and is connected to the supply piping by means of a connector for 

Содержание Sierra SR-10-60

Страница 1: ... 48 SR 4B 36G 60 SR 6B 24G 60 SR 6B 24RG 60 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS RANGE 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE108 MIAMI FL 33181 TEL 786 600 4687 1 844 218 8477 sales mvpgroupcorp com www mvpgroupcorp com ...

Страница 2: ...ARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lis...

Страница 3: ...and cannot be adjusted If converting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Me...

Страница 4: ...as Fuel ANSI Z21 41 or Quick Disconnect Devices for Use with Gas Fuel CANI 6 9 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit HIGH SHELF ASSEMBLY 1 Mount the back guard flue riser ...

Страница 5: ...y valve and then to the pilot burner Gas flow is controlled by the safety valve Oven pilot lighting or relighting is to be completed in the following sequence 1 Turn the oven thermostat knob to off and wait 5 minutes 2 Remove the oven s lower kick plate by lifting up and out This exposes the pilot safety valve and the igniter button 3 Make sure any accumulated gas has dispersed Since propane gas i...

Страница 6: ...e oven liner panels Wash all the above with hot soapy water then reassemble Baked on spills may be loosened and stubborn stains removed with ordinary household ammonia and scrubbing with a nylon pad in a cold oven only Do not allow spray type oven cleaners to come into contact with the temperature probe in the oven After cleaning the oven rinse well with 1 4 cup of vinegar to one quart of clear wa...

Страница 7: ...ss than under any circumstances All connections must be tested with a soapy water solution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas supplier or the appl...

Страница 8: ...ly piping system at test pressure equal to or less than psi 3 45kpa CLEARANCES The appliance area must be kept free and clear of all combustibles SR Series products are for installation in Non Combustible locations only COMBUSTIBLE NON COMBUSTIBLE SIDES 12 Inches 0 Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inches AIR SUPPLY VENTILATION The area in front of around and above the appliance must ...

Страница 9: ...ers operating gas pressure in inches WC and whether the appliance is orifices for natural or propane gas When communicating with factory about a unit or requesting for special parts or information Rating plate data is essential for proper identification SIERRA COOKING APPLIANCES MUST BE CONNECTED ONLY TO THE TYPE OF GAS ACCESSORIES INSTALLATION BACKSPLASH AND SHELF INSTALLATION MODELS SRR 4 24 SRR...

Страница 10: ... INSTALLATION Identify the assemblies to be fitted over the equipment Make sure you have all the tools and fasteners listed Item Description Quantity PC 1 M6 SCREW FLAT 2 2 HEX SCREW 10mm 10 Flat screwdriver Hex Nutdriver ...

Страница 11: ...11 to 17 Remove the 3 rear screws of the unit Place the backsplash and make sure that the manifold fits in the hole on the right side support push ...

Страница 12: ...12 to 17 Place and tight the hex screws in the shown positions SHELF INSTALLATION Place the shelf over the backsplash and hook it on the very top of it Back Splash Shelf ...

Страница 13: ...13 to 17 Fit the M6 screws on the inside of the shelf to secure it in position REMOVE THE DOOR ...

Страница 14: ... in both hinges you can find 2 pieces of it in carton legs box STEP 2 Hold onto both hinges with your hands STEP 3 Raise the door until the door is at a 45 degrees angle STEP 4 Pull the door towards you and lift up To put the door back in reverse these instructions ...

Страница 15: ...FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GAS PRESSURE INCREASE GAS PRESSURE TO...

Страница 16: ...Sierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional...

Страница 17: ...7 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canada H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...

Отзывы: