High Volume/Output RTM Systems Operations Manual
Page | 19
Innovator II Control Panel
Control Name
Type of Control
Function
CAT/OP
Indicator Light
Will turn red if overpressure state exists.
RGA Alarm
Indicator Light
Will turn red if gel alarm timer has expired.
Flush Button
Push Button
Press this button to operate the flush cycle
Mold Pressure
Guard
Preset Level Gauge
Displays signal air pressure being supplied to the Mold Pressure
Guard (MPG) control.
Mold Pressure
Guard
Regulator
Use this to adjust the MPG control signal air pressure.
Inject Button
Push Button
Press this button to start the machine in inject mode.
Recirculate Button Push Button
Press this button to start the machine in recirculation mode.
Stop Button
Push Button
Press this button to stop the machine in injection, recirculation, or
flush mode.
Stroke Count
Counter
Displays the current number of strokes the pump has performed.
Stroke Count
Preset Count
Counter
Displays the number of strokes at which the unit will shut down
when reached.
Stroke Count Digit
Modifiers
Spin Buttons
Click up or down to adjust the number in the Preset Count column
to set the stroke count the machine should stop at.
Digit Lockout
Button
Press this button to keep the stroke count setting.
Reset Button
Push Button
Press this button to reset the current stroke count.
RESET BUTTON
CURRENT COUNT DISPLAY
PRESET COUNT DISPLAY
DIGIT LOCKOUT
DIGIT MODIFIERS
Figure 2. Stroke Counter