Troubleshooting 

The following table describes some of the symptoms, probable causes and possible solutions in regard to 
the installation of the ProDigital Network controller. 

Also,  please  download  and  read  the  latest  500811  ProDigital Network Controller  product manual from 
the MuxLab web site. 

Symptom 

Probable 

Cause 

Possible 

Solution 

No power LED 

No power to the unit 

Verify that the power supply is connected to the 

unit, and if the AC adaptor is connected to the 
power source. 

Red power LED 

Unit is off  
Boot failure 
or unit was shutdown 

Press the power button to turn on the unit. 
The power LED should change from red to blue 

after a short period and will then complete the 
power-up sequence within approximately 60 sec.  

Unable to connect to 
web page 

Bad network cable  
or wrong IP address 

The controller and host computer need to be in the 

same local IP network to be able to communicate. 

Unable to connect to 
web page 

Unknown IP address 

Connect a keyboard and monitor to the controller. 

 

Press enter on the keyboard and check the 

controller IP address displayed on the monitor. 
 

If IP address is not shown, then make sure the 

Ethernet cable is good and properly connected, 
and then reboot the unit by cycling the AC 
power. 

If  you  still  cannot  diagnose  the  problem, please call MuxLab Customer Technical Support at 877-689-
5228 (toll-free in North America) or (+1) 514-905-0588 (International). 