Installation 

1.

 

Identify the connectors on the Transmitter (LC Fiber out) and Receiver (LC FIBER in) 
as indicated on the product labels. 

 

2.

 

Verify  that  the  distance  between  the  Transmitter  and  Receiver  is  within  MuxLab 
specifications (see Specifications table). 

3.

 

To install the Transmitter: 

3a.

 

Connect  the  Transmitter  to  the  SDI  video  source  with  a  BNC  75-ohm  coaxial 
cable. Respect the cable distance shown in the specifications table. 

3b.

 

Remove  the  white  protective  plug  from  the  LC  connector.  Connect  one  LC 
connectorized  singlemode  optical  fiber  cable.  Keep  the  protective white  plug and 
place it back on the LC connector if the fiber is later removed or not present.  

3c.

 

DO NOT LOOK into the fiber or module when the power is on. 

3d.

 

Plug  a  power  supply  or  the  special  power  cable.  The  special  power  cable  has  a 
locking mechanism, push the plug and rotate the lock it until it is secure. 

4.

 

To install the Receiver: 

4a.

 

Connect the Receiver to the SDI display equipment with a BNC 75 ohm compliant 
cable. Respect the cable distance shown in the specifications table. 

4b.

 

Remove the protective  white plug.  Connect the remaining end side of the fiber to 
the Receiver. Keep the protective white plug and put it back if the fiber is removed 
or not present. 

4c.

 

Plug  a  power  supply  or  the  special  power  cable.  The  special  power  cable  has  a 
locking mechanism, push the plug and rotate the lock it until it is secure.  

5.

 

Power the equipment and verify the image quality. Verify if both power LEDs are 
ON.  With  a  valid  source  check  that  both  the  Transmitter  Signal  LED  and  the 
Receiver Signal LED are ON. 

 

 

 

 

Troubleshooting 

The following table describes some of the symptoms, probable causes and possible solutions 
with respect to the installation of the 3G-SDI Extender Kit: 

LEDS 

Status 

Possible cause 

Action 

Power LED 
(both TX & 
RX units) 

OFF 

No AC power or 
defective power supply. 

Try replacing the two power 
supplies. 

Signal LED 
(TX unit) 

 

 

OFF 

 

No source signal or 
incompatible signal. 

 

Check source signal. 

Check coax cable. It must be 75 
ohm and the length must be less 
than 330ft (100m). 

Signal LED 
(RX unit) 

 

 

OFF 

 

No source signal or 
incompatible signal. 

Fiber not connected or 
broken. 

Remote unit off or 
defective. 

Check source signal. 

Check fiber cable. 

Check distance specs for fiber 
cable (see specifications table). 

Power & 
Signal LED 
(both TX & 
RX units) 

ON but no 
signal on 
monitor 

 

Display monitor not 
working. 

Coax cable not 
connected or broken. 

Try another monitor. 

Check coax cable. It must be 75 
ohm and the length must be less 
than 330ft (100m). Some 
equipment may not support 
distances up to 330ft (100m). Try a 
shorter distance to confirm. 

 

If you still cannot diagnose the problem, please call MuxLab Customer Technical Support at 
877-689-5228 (toll-free in North America) or (+1) 514-905-0588 (International). 

 