3.10.4 Replacing Wiper Solenoid Cable
160
3.10 Replacing Maintenance
VJ628XE-M-00
3.10.4
Replacing Wiper Solenoid Cable
●
Tools & Jigs & Maintenance part
㨀㧵㧼
In this section describes the procedure to replace the maintenance part, Wiper SOL
Cable Assy. In this section, it is referred to as Wiper solenoid cable.
Name
No.
Remarks
Wiper SOL Cable Assy
DG-44723 Exploded View Maintenance
Phillips screwdriver No.2
Generic
products
-
1
Removing R Side Cover.
2
Move Carriage to the opposite side of Platen.
3
Remove Top Cover.
4
Remove Wiper Solenoid Relay Cable from
Wiper Solenoid.
A : the cable of Wiper Solenoid
B : Connecting point
B
A
DCEMUKFGQH/CKPVGPCPEG
NOTE
Wiper solenoid and Wiper solenoid Cable
are connected in the post header
assembly. Please do not lose the post
header assembly.
5
Remove the Wiper solenoid cable from the
clamps on the path.
6
Remove the Wiper solenoid cable from the
Main board Assy.
7
To reassemble unit, reverse the removal
procedure.
J29