background image

MUTEC GmbH assumes no liability for any incorrect information given in this manual. Please note that 
all software/hardware product names are registered trademarks of their respective owners. No part of 
this manual may be reproduced, copied or converted to a machine-readable form or electronical media 
without a written permission of MUTEC GmbH. We reserve the right to change or improve our products 
without prior notice. © MUTEC GmbH 2009–2013

WARRANTY REGULATIONS

§1 Warranty

 

MUTEC GmbH warrants the flawless performance of this product to the original buyer for a period of two (2) years from the date of purchase. If any failure occurs within 
the specified warranty period that is caused by defects in material and/or workmanship, MUTEC GmbH shall either repair or replace the product free of charge within 90 
days. The purchaser is not entitled to claim an inspection of the device free of charge during the warranty period. If the warranty claim proves to be justified, the product 
will be returned freight prepaid by MUTEC GmbH within Germany. Outside Germany, the product will be returned with the additional international freight charges payable 
by the customer. Warranty claims other than those indicated above are expressly excluded.

§2 Warranty transferability

 

This warranty is extended exclusively to the original buyer who bought the product from a MUTEC GmbH specialized dealer or distributor, and is not transferable to anyone 
who may subsequently purchase this product. No other person (retail dealer, distributor, etc.) shall be entitled to give any warranty promise on behalf of MUTEC GmbH.

§3 Waranty regulations

 

The return of the completed registration card, or online registration on one of the websites specified below, is a condition of warranty. Failing to register the device before 
returning it for repair will void the extended warranty.

The serial number on the returned device must match the one stated on the registration card or entered during online registration. Otherwise, the device will be 
returned to the sender at the sender’s expense. 
Any returned device must be accompanied by a detailed error description and a copy of the original sales receipt issued by a MUTEC dealer or distributor. 
The device must be returned free of shipping expenses and in the original package, if possible; otherwise, the sender has to provide comparably protective packaging. 
The sender is fully responsible for any damage or loss of the product when shipping it to MUTEC GmbH. 

§4 Limitation of warranty

 

Damages caused by the following conditions are not covered by this warranty:

Damages caused by every kind of normal wear and tear (e.g. displays, LEDs, potentiometers, faders, switches, buttons, connecting elements, printed labels, cover 
glasses, cover prints, and similar parts). 
Functional failure of the product caused by improper installation (please observe CMOS components handling instructions!), neglect or misuse of  

 

the product, e.g. failure to operate the unit in compliance with the instructions given in the user or service manuals. 
Damage caused by any form of external mechanical impact or modification. 
Damage caused by the user’s failure to connect and operate the unit in compliance with local safety regulations. 
Damage caused by force majeure (fire, explosion, flood, lightning, war, vandalism, etc.). 
Consequential damages or defects in products from other manufacturers as well as any costs resulting from a loss of production.

Repairs carried out by personnel which is not authorized from MUTEC GmbH will void the warranty. Adaptations and modifications to the device made with regard to 
national, technical, or safety regulations in a country or of the customer do not constitute a warranty claim and should be set with MUTEC GmbH in advance. 

§5 Repairs

 

To obtain warranty service, the buyer must call or write to MUTEC GmbH before returning the unit. All inquiries must be accompanied by a description of the problem and 
the original buyer’s invoice. Devices shipped to MUTEC GmbH for repair without prior notice will be returned to the sender at the sender’s expense. In case of a functional 
failure please contact:

MUTEC Gesellschaft fuer Systementwicklung und Komponentenvertrieb mbH 
Siekeweg 6/8  •  12309 Berlin  •  Germany  •  Fon 030-746880-0  •  Fax 030-746880-99  •  [email protected]  •  www.MUTEC-net.com

JET and Jitter Elimination Technology are trademarks of TC Applied Technologies Ltd.  The JET tech-
nology is used under sublicense from TC Applied Technologies Ltd., and is the intellectual property of 
Sonopsis Ltd.  Applicable patents include WO2004088845.

SAFETY INSTRUCTIONS

General instructions 

 

To reduce the risk of fire or electrical shock, do not expose this appliance to rain or moisture, direct 
sunlight or excessive heat from sources such as radiators or spotlights. No user serviceable parts are in-
side. Repair and maintenance must be carried out by qualified personnel authorized by MUTEC GmbH! 
The unit has been designed for operation in a standard domestic environment. Do NOT expose the unit 
and its accessories to rain, moisture, direct sunlight or excessive heat produced by such heat sources as 
radiators or spotlights! The free flow of air inside and around the unit must always be ensured.

Initial operation

 

Prior to the initial operation of the unit, the appliance, its accessories and packaging must be 
inspected for any signs of physical damage that may have occurred during transit. If the unit has 
been damaged mechanically or if liquids have been spilled inside the enclosure, the appliance may 
not be connected to the mains or must be disconnected from the mains immediately! If the unit is 
damaged, please do NOT return it to MUTEC GmbH, but notify your dealer and the shipping com-
pany immediately, otherwise claims for damage or replacement may not be granted.

If the device is left in a low-temperature environment for a long time and then is moved to a room-
temperature environment, condensation may occur on the inside and the exterior. To avoid short- 
circuits and flashovers, be sure to wait one or two hours before putting the device into operation.

Power supply

 

The device contains a self-adapting wide-range power supply supporting the majority of global stan-
dard line voltages within a range of 90…250 V, with no need for making adjustments. Make sure that 
your line-voltage source provides a supply voltage within the specified range. In addition, make sure 
that the device is properly grounded via the local electric installation.

Please use the enclosed power cord (see packaging) to connect the unit to the mains. Switch the 
unit off before you attempt to connect it to the mains. Connect the power cord to the unit, then 
to a standard 3-pin mains outlet. To draw the power cord, never pull on the cable but on the mains 
plug!

The unit must be grounded during operation!
For information on the power-inlet wiring, refer to the »Wiring of connectors« section in the 
appendix. Disconnect the device from the mains when not using it for an extended period!

This symbol, an exclamation mark inside a triangle, 
alerts you to important operating or safety instructions 
in this manual.

This symbol, a flash of lightning inside a triangle, alerts 
you to the presence of uninsulated dangerous voltage 
inside the enclosure - voltage that may be sufficient to 
constitute a risk of shock.

Declaration of Conformity

 

We herewith confirm that the product complies with the European 
Commission’s standards on electromagnetic compatibility.

Interference emission:    

EN 50081-1, 1992 

Resistance to interference:  

EN 50082-1, 1992

Presupposed as operation condition is that all clock outputs are con-
nected with high-quality and good shielded BNC 75 ohms cable.

!

R I S K   O F

ELECTRICAL SHOCK!

C A U T I O N

!

Содержание MC-7

Страница 1: ...WORD CLOCK DISTRIBUTION AMPLIFIER AUDIO CLOCK CONVERTER...

Страница 2: ......

Страница 3: ...epairs To obtain warranty service the buyer must call or write to MUTEC GmbH before returning the unit All inquiries must be accompanied by a description of the problem and the original buyer s invoic...

Страница 4: ......

Страница 5: ...Menus and setting Functions 13 Steps of Operation 13 OPERATING THE MC 7 REFERENCE CLKMULTIPLIERS Menus 15 General Operation Procedure 15 Word Clock as Input Reference including Options 16 AES3 11 as I...

Страница 6: ......

Страница 7: ...tstanding digital audio clock distributor and converter enabling to handle every clocking issue in your studio set up with ease MC 7 Features Distributes and converts Word Clock AES3 11 and S PDIF Ext...

Страница 8: ...sync master clock generator The unit provides different high stable clock signals for simultaneous synchronization of digital audio and SD video devices MC 3 2 The MC 3 2 SMART CLOCK HD is an universa...

Страница 9: ...rmine the factor by which the basis clock rate of the incoming reference signal is multiplied additionally This setting can be made individually for every Word Clock pair of outputs as well as for the...

Страница 10: ...S11 signal in compliance with AES3 1992 R1997 or AES11 1997 2003 The input imped ance is 110 XLR connector female For selecting this input see chapter OPERATING THE MC 7 5 S P DIF IN These two S P DIF...

Страница 11: ...have no termination of the Word Clock input e g RME Hammerfall with Word Clock i o Alesis BRC or M Audio ProFire Light bridge you can use an additional BNC T piece to terminate the input Plug the T p...

Страница 12: ...optical fiber cables Here you can use both plastic and glass fiber based cables When using plastic fiber cables lengths of 10 meters should not be exceeded so as to ensure the reliable transmission o...

Страница 13: ...ordingly and the corresponding function is vailable at once 3 When the needed function is selected do not press the switches again After a period of approx 4 seconds the LED in front of the selected f...

Страница 14: ......

Страница 15: ...ral Operation Procedure The MC 7 menu is strictly organized aligned to generally usual handling procedures when inserting such a box into your studio set up So you can split up all of the necessary ad...

Страница 16: ...5 4 3 2 S P DIF op AES3 11 WCLK S P DIF co REFERENCE REF PASS HOLD x256 x2 x1 x4 CLKMULTIPLIERS 1 6 5 4 3 2 S P DIF op AES3 11 WCLK S P DIF co REFERENCE REF PASS HOLD x256 x2 x1 x4 CLKMULTIPLIERS 1 6...

Страница 17: ...e output of all outgoing signals S P DIF op AES3 11 WCLK S P DIF co REFERENCE REF PASS HOLD x256 x2 x1 x4 CLKMULTIPLIERS 1 6 5 4 3 2 When pressing the SELECT key again you can activate the REF PASS fu...

Страница 18: ...ou can activate the HOLD function which leads to a fail safe output of all outgoing signals S P DIF op AES3 11 WCLK S P DIF co REFERENCE REF PASS HOLD x256 x2 x1 x4 CLKMULTIPLIERS 1 6 5 4 3 2 When pre...

Страница 19: ...comes in the system identifies the included base clock rate and sets the multiplier accordingly to output only 44 1kHzx256 or 48 0kHzx256 The factory default is set at x1 CLKMULTIPLIER 5 For the AES3...

Страница 20: ...at 176 4kHz or 192 0kHz STATUS This area displays different system conditions of your MC 7 There is no access for changing settings LOCK This blue LED lights when the internal PLL circuit has detecte...

Страница 21: ...A green 3 Live phase brown USA black 2 3 1 3 2 1 Ground 2 a conductor hot 3 b conductor cold AES EBU XLR Output Word Clock Suber Clock BNC Input Output 1 Signal 2 Ground 1 2 S PDIF Cinch Output 1 Audi...

Страница 22: ...3 pin socket JP1 When moving the jumper from position 2 to position 1 the input termi nation will be switched off Therefore the MC 7 must be connected in a chain in which a device with terminated inpu...

Страница 23: ...Clock Signal 5 AES3 11 44 1kHz 88 2kHz 176 4kHz None AES11 blank frame none audio 6 S P DIF op co 44 1kHz 88 2kHz 176 4kHz None S P DIF blank frame none audio AES3 DIGITAL AUDIO SIGNAL AS INPUT REFER...

Страница 24: ...blank frame none audio 6 S P DIF op co 44 1kHz 88 2kHz 176 4kHz None S P DIF blank frame none audio S P DIF COAXIAL DIGITAL AUDIO SIGNAL AS INPUT REFERENCE HOLD FUNCTION Outputs Multiply x1 Multiply x...

Страница 25: ...76 4kHz None S P DIF blank frame none audio S P DIF OPTICAL DIGITAL AUDIO SIGNAL AS INPUT REFERENCE REF PASS FUNCTION Outputs Multiply x1 Multiply x2 Multiply x4 Multiply x256 Output Signal 1 Word Clo...

Страница 26: ...1 x XLR male transformer balanced 3 5Vpp 110 output impedance 110 buffered Format Resolution AES3 1992 2003 AES11 1997 2003 24bits Transmitted sampling rates 25 0kHz to 200 0kHz S P DIF COAXIAL OUTPU...

Страница 27: ......

Страница 28: ...PRODUCT NAMES ARE REGISTERED TRADEMARKS OF THEIR RESPECTIVE OWNERS WE RESERVE THE RIGHT TO CHANGE TECHNICAL DETAILS WITHOUT PRIOR NOTICE MUTEC GmbH 2002 7045 014 WWW MUTEC NET DE FON 0049 0 30 746880...

Отзывы: