3. Specification

 

The instrument specifies one year as a cycle, and shall 

be re-calibrated under 18

℃ ~ 

28

, with relative humidity 

less than 75%.

 

3.1 Overview   

Select measurement function and range automatically.

● 

Overload protection throughout the range.

 

● 

Max.  voltage  between  measurement  terminal  and 

ground: 600V

 

DC or 600V AC

 

● 

Operating height: Max. 2000m

 

● 

Display: LCD

 

● 

Max. display value: 6000 digit.

 

● 

Polarity  indication:  Automatic  indication,  and  ‘-’ 

indicates negative.

 

● 

Over range display: ‘0L’ or ‘-0L’.

 

Sampling  time:  About  3  times/second.,bargraph  10

times/second

  

● 

Unit  display:  Function  and  electricity  quantity  unit 

display.

 

● 

Automatic shutdown time: 15 minutes

 

● 

Power supply: 1.5V AAA battery × 

2

 

● 

Battery  under-voltage  indication:  LCD display

 

symbol

  

● 

Temperature coefficient: Less than 0.1×accuracy/

● 

Operating temperature: 18

℃ ~ 

28

.

● 

Storage temperature: -10

℃ ~ 

50

.

5

Содержание FS8330Pro

Страница 1: ...Intelligent digital clamp multimeter SEL NCV INPUT CAT MAX 600V COM AUTO 6000Counts NCV MAX 400A CAT II 600V CATIII 300V...

Страница 2: ...7 DIODE 3 2 10 Frequency 3 2 9 Temperature 3 2 6 Resistance 3 2 4 AC voltage 3 2 2 DC current Optional features 3 2 1 AC current 3 2 3 DC voltage 3 2 5 Line on off test 3 2 8 Capacitor 1 16 16 10 5 5...

Страница 3: ...61010 2 030 and EN 61010 2 032 level II pollution and over voltage standard is CAT II 600V Please observe safety operation guide and guarantee to use instrument in a safe manner 1 1 Preparation 1 1 1...

Страница 4: ...ation could only be conducted by technicians fully understanding the instrument and electric shock danger 1 3 2 Before opening instrument bottom case or battery cover remove the pens from the wire bei...

Страница 5: ...nd ashlight button Eletric torch Input socket Caution light Contactless induction zone LCD display SEL and NCV buttons Current measuring clamp On o key SEL NCV INPUT CAT MAX 600V COM AUTO 6000Counts N...

Страница 6: ...Automatic shutdown indication Low battery Reading hold state Volt voltage ampere current Ohm kilohm and megohm resistance hertz icrofarad Centigrade and Fahrenheit LCD display DIODE AUTO 6000Counts No...

Страница 7: ...0V AC Operating height Max 2000m Display LCD Max display value 6000 digit Polarity indication Automatic indication and indicates negative Over range display 0L or 0L Sampling time About 3 times second...

Страница 8: ...rrent Optional features Range Resolution Accuracy 60A 0 01A 2 5 reading 8 digits 400A 0 1A Min input current 0 2A DC current Max input current 400A DC current 3 2 3 DC voltage Range Resolution Accurac...

Страница 9: ...eading 5 digits Min input voltage 0 1 mV AC Max input voltage 600V AC valid value AC voltage AC voltage Line on off test Range Resolution Function 1 Overload protection 250V DC or AC valid value If th...

Страница 10: ...00mF 1 F 60 00mF 10 F Overload protection 250V DC or AC valid value 10 reading 40digits 2 5 reading 20digits 3 2 9 Temperature Range Resolution Accuracy 1 1 reading 3 2 1 reading 3 Overload protection...

Страница 11: ...uracy Range Resolution Accuracy 1 reading 5 digits 1 reading 5 digits Measurement range 40Hz 1000Hz Input signal range 1 4 Full scale Value Via gear V Measurement range 40Hz 1000Hz Input signal range...

Страница 12: ...it is required to hold reading touch button value on display will be locked touch button again to cancel reading hold 4 2 Torch 1 4 3 10 Long press the ashlight button for 2 seconds turn on the ashli...

Страница 13: ...resent Do not rely on the non contact voltage to determine whether a wire has a voltage Probe operation may be in uenced by socket design type of insulation thickness etc In NCV detection mode the met...

Страница 14: ...current value and frequency value of the measured conductor Note The meter can display the frequency value only when the current value is greater than 35A Dc current measurement Press the clamp open t...

Страница 15: ...V the instrument shows mV Dc voltage measurement Connect the test pen to the test signal When the test signal is 600mV the instrument will display the current dc voltage value under test when the test...

Страница 16: ...the measured current dc voltage value When the measurement signal is 600mV the instrument displays OL Ac voltage measurement resistance measurement Connect the test pen to the resistance to be measure...

Страница 17: ...15...

Страница 18: ...old battery 4 Place the battery cover Do not reverse battery polarity 16 5 2 Change pens Warning When changing the pen it is required to replace with an identical pen or a pen of the same level The pe...

Отзывы: