 Owner’s Manual

MD3090 and MD3095

 

Compact Tactical 

Life Preserver

 

*Shown with the MA3090 Chest Belt/Crotch Strap Assembly

Содержание MD3090

Страница 1: ...Owner s Manual MD3090 and MD3095 Compact Tactical Life Preserver Shown with the MA3090 Chest Belt Crotch Strap Assembly ...

Страница 2: ...90 8 Usage in Freezing Conditions 8 Is Your LP in Good and Servicable Condition 9 Care and Maintenance Instructions 10 Safety Accessories 10 Cleaning and Storing of Your LP 10 How and Why to Test Your LP 10 How Do You Test Your LP Using the Manual Inflator 11 How Do You Test Your LP Using the Oral Inflator 12 Integration Instructions with Body Armor 15 Attachment Instructions for MA3090 Chest Belt...

Страница 3: ...to self right and float the wearer It is always recommended that users perform their own in water test with full gear The Mustang Survival MD3090 and MSD3095 can be attached to a body armor vest or worn as a stand alone life preserver using the chest belt crotch strap assembly MA3090 The MD3090 and MD3095 will not inflate automatically upon immersion The beaded handle must be pulled to activate in...

Страница 4: ...owing these steps 1 Undo the Velcro tabs on the wearer s right hand side of the collar to expose the inflator Fig 3 Compact Tactical Life Preserver Owner s Manual 2 3 FIGURE 3 CO2 Cylinder Manual Inflator Lever In Up and Ready Position Green Indicator Pin Lanyard Beaded Handle Manual Inflation System FIGURE 1 CO2 Cylinder Manual Inflator Lever In Up and Ready Position Green Indicator Pin Lanyard B...

Страница 5: ...er s left hand side of the collar to expose the oral inflator Check that the oral inflation dust cap is properly in the stowed position Fig 5 Dust cap in deflation position Dust cap in stowed position FIGURE 5 5 Reposition the inflator s protective cover and repack P 7 If everything checks out according to the preceding instructions your LP is ready for use Sizing and Fit The LP provides 33 7 lbs ...

Страница 6: ...llowing procedures are used to inflate your MD3090 or MD3095 1 Manual inflation Actuate the inflation system by jerking firmly downward on the beaded handle The LP should fully inflate within 5 seconds Fig 6 MD3090 Inflation FIGURE 6 2 Oral inflation Properly armed and inspected manual MD3090 LP models will inflate However should inflation not occur or in a nonemergency situation you can fully inf...

Страница 7: ...RE 8 1 Unscrew and inspect the CO2 cylinder If used or damaged discard the CO2 cylinder Fig 4 2 Check the manual lever to ensure it is in the up and ready position with the green indicator pin properly installed If the green indicator pin is missing or damaged replace it Fig 5 3 Install an unused CO2 cylinder by screwing it into the top of the inflator and hand tighten Do not over tighten as this ...

Страница 8: ...nsure that the CO2 cylinder has not been pierced Fig 10 4 Raise and hold the lever into the inflator housing 5 Install a new cylinder bayonet assembly by engaging bayonet tabs in housing pushing in and turning clockwise 1 8 turn to a full stop Fig 9 Tab Piercing Pin Cylinder Lever Service Indicator MD3081 and MD3082 Manual Inflator 1 8 Turn FIGURE 9 6 Examine the service indicator Fig 8 Ensure the...

Страница 9: ...he inflation tube dust cap back in its normal position on the oral inflation tube Fig 5 Cap In Deflate Position FIGURE 10 Repacking Your MD3090 and MD3095 Before repacking completely deflate the inflation cell Force excess air out through the inflation tube Fig 7 Do not wring cell Put the inflation tube cap back in the stowed position Fig 5 NOTE Before following the repacking sequence be sure to p...

Страница 10: ...freezing a fully discharged cylinder may not adequately inflate your MD3090 or MD3095 LP Oral inflation may be required to fully inflate the LP in freezing conditions WARNING CO2 inflation could over pressurize and damage your LP if already fully orally inflated IS YOUR LP IN GOOD AND SERVICEABLE CONDITION Check your LP between outings to be sure that it is properly armed that it is free of rips t...

Страница 11: ...D3095 and hold the valve under water If bubbles appear deflate and reinflate to test again Should the leak persist take your MD3090 or MD3095 to the point of purchase for proper servicing 6 Visually examine your MD3090 or MD3095 for damage or excessive abrasion wear tear or contamination Particular attention must be paid to the stitching If in doubt send it to the point of purchase for evaluation ...

Страница 12: ...ry place out of direct sunlight How and Why to Test your LP Inflate your LP and try it out in the water to Make sure it floats you Comfortably when worn properly Adequately for expected operations Body shapes densities affect performance Make sure it works A flow of bubbles should not appear see CARE AND MAINTENANCE INSTRUCTIONS for leak tests P 9 It should inflate quick and easily Learn how it wo...

Страница 13: ...or 1 To test your inflatable LP you will not need any spare parts or re arming kits 2 Remove the CO2 cylinder to prevent inadvertent activation of the manual inflation system which could potentially damage the LP Inspect the threaded end to confirm it is unused 3 Put on the LP 4 Get into shallow water just deep enough that you can stand with your head above the surface 5 If you are a weak swimmer ...

Страница 14: ...n Instructions with Body Armor 1 Lay the body armor vest down on a clean flat surface with the back of the vest facing up Lift up the emergency extraction strap on the back of the vest and loop the back attachment of the MD3090 Life Preserver around the extraction strap Fig 17 FIGURE 17 2 Secure the MD3090 back attachment strap with the snap Fig 18 FIGURE 18 Compact Tactical Life Preserver Owner s...

Страница 15: ... the Life Preserver perpendicular to the webbing running across the vest Fig 20 FIGURE 20 4 Feed the male buckle through the 3rd and 4th row of webbing at the second loop from the outside edge Insert the female buckle through the same place in the 3rd row of webbing Fig 21 Ensure the webbing is not twisted Row 3 Row 4 FIGURE 21 12 13 Compact Tactical Life Preserver Owner s Manual ...

Страница 16: ...at for the other side Row 3 Row 4 FIGURE 22 Additional Steps a Fasten the buckle that connects the left and right lobes in front of the chest section of the vest Cinch by pulling on the loose end of the webbing Fig 23 FIGURE 23 b Ensure all buckles are securely fastened and webbing adjustments are tight Compact Tactical Life Preserver Owner s Manual 14 15 ...

Страница 17: ...ight male buckle as worn C Left male buckle as worn D T tab junction with snap Fig 24 A C B D FIGURE 24 2 Insert the short side of the webbing attachment on the back of the MD3090 life preserver through Looploc A on back strap of the chest belt accessory Fig 25 Securely fasten the snap A FIGURE 25 14 15 Compact Tactical Life Preserver Owner s Manual ...

Страница 18: ...h the snap Once the snap is securely fastened turn the snapped portion so it is positioned inside the chest belt loop away from the body Fig 26 D FIGURE 26 4 Click the male buckle attachment C into corresponding female buckle on the front of the chest belt Fig 27 C FIGURE 27 Compact Tactical Life Preserver Owner s Manual 16 17 ...

Страница 19: ... preserver on as shown Fig 29 7 Buckle chest buckle that connects the right and left lobes of the life preserver Fig 30 8 Buckle chest belt Fig 31 FIGURE 29 FIGURE 31 FIGURE 30 9 Bring crotch strap to the front between the legs and securely buckle to chest strap Fig 32 16 17 Compact Tactical Life Preserver Owner s Manual ...

Страница 20: ...FIGURE 32 Compact Tactical Life Preserver Owner s Manual 18 19 ...

Страница 21: ...18 19 Compact Tactical Life Preserver Owner s Manual ...

Страница 22: ... and seahorse design is a registered trademark of Mustang Survival Corp Our commitment to quality has earned our Richmond facilities ISO 9001 registration the highest of all international standards This is our guarantee you re receiving the ultimate in design and manufacturing HT 1096 Printed in Canada Rev Oct 21 05 WE SAVE LIVES FOR A LIVING ...