-1-

GENERAL PRECAUTIONS

1 .Before using it, read all instructions and markings:
   (1) UPS  (2) the batteries  (3) this manual
2. Do not expose it to rain, snow or liquids of any type. It is designed for indoor.
3. Do not disassemble it. Take it to a qualified service center when service or repair is required.
4. To prevent the risk of electric shock, disconnect all wiring before attempting any maintenance 
    or cleaning. Turning off the unit will not reduce this risk.
5. Input/output AC wiring must be no less than 16 AWG gauge copper wire and rated for 75 °C or 
   higher. 

PERSONNEL PRECAUTIONS

 

1 .Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
2. Avoid touching eyes while working near batteries.
3. NEVER smoke or allow a spark or flame in vicinity of a battery.
4. Remove personal metal items such as rings, bracelets, necklaces, and watches when working 
    with batteries. Batteries can provide heavy short-circuit current, enough to make metal melt 
    and causes severe burn.
5. If a remote or automatic generator start system is used, disable the automatic starting circuit 
    or disconnect the generator to prevent accident during servicing.

FOLLOW STANDARD.

EN 60950-1:2006+A2:2013+A11:2009+A1:2010+A12:2011
EN 55022:2010. EN 55024:2010. EN 61000-3-3:2008

LED/Buzzer

LCD

Explanation / Possible cause What to do

Buzzer beeps
And red LED is 
off

Battery voltage is too Low.

Charge the unit at least 8 hours.

Over load.

Decrease your load.

Buzzer beeps
continuously 
and red LED is 
on.

Fault code 02

Temperature of machine is 
too high.

Power off and waiting for 
minutes.

Fault code 03

battery voltage is too high. Check the battery specifications.

Fault code 04

battery voltage is too low.

Check the battery specifications.

Fault code 05

Output short circuited.

Remove your load and restart.

Fault code 06

Inverter output voltage is 
high.

Return to repair center.

Fault code 07

Over load.

Decrease your load.

Fault code 11

Main relay fault.

Fault code 41

Input voltage too low.

Fault code 42

Fault code 42

Fault code 44

Input voltage too high.

Input frequency too low.

Input frequency too high.

Check input power.

Output short circuited.

Output voltage is too low.

Check if wiring is connected well 
and remove abnormal load.

Decrease your load.

Fault code 51

Fault code 58

Fault code 45

Restart the machine. If it still 
can’t work, please return to
 repair center.

AVR fault.

Restart the machine. If it still 
can’t work, please return to 
repair center.

Blink load ICON

Blink battery ICON

COMMUNICATION

Refer to User Guide of PowerMonitor.

TROUBLE SHOOTING

If machine enters into fault mode, please remove input power. And according to the table, deal 
with the following problems.

-10-

Содержание EW20-750VA Pro

Страница 1: ...750VA 1000VA 1500VA 420 00282 00 UPS Appliances PC TV Light Electric fan UPS...

Страница 2: ......

Страница 3: ...NPUT Frequency Range OUTPUT Transfer Time Waveform BATTERY Battery capacity Maximum Charge Current PHYSICAL Dimension D W H mm Net Weight kg 473 x 213 x 283 750VA 1500VA sine wave 230VAC 5 50Hz 5Hz or...

Страница 4: ...2 2010 EN 55024 2010 EN 61000 3 3 2008 LED Buzzer LCD Explanation Possible cause What to do Buzzer beeps And red LED is off Battery voltage is too Low Charge the unit at least 8 hours Over load Decrea...

Страница 5: ...as frequency buzzer etc Features Sine wave UPS Friendly HMI 3 steps charging algorithm MFD multi function display Overload and short circuit protection Deep discharge protection Automatic voltage reg...

Страница 6: ...below chart is on the front panel of the inverter It includes four front indicators three function keys and a LCD display indicating the operating status and input output power information 8 Operating...

Страница 7: ...iption Grid frequency type 50Hz default 60Hz 04 7 Setting program information Program Value LCD Setting After pressing and holding ENTER button for 2 seconds the unit will enter setting mode Press ENT...

Страница 8: ...tes overload Indicates the load level by 0 25 25 45 50 75 and 75 100 0 25 25 50 50 75 75 100 Mode operation information Buzzer information Buzzer state is silence Buzzer state is normal Selectable Inf...

Отзывы: