ྜG

When the DATA receiving is successful and the EFX LITE 6M Audio Controller will automatically restart.

8. Initial Default Setting

The initial default setting for the EFX LITE 6M Audio Controller may be reset with the following procedure. 

This procedure will erase all user data from the EEPROM memory.

ྙG

Apply power while holding the P1 and P4 switches down.

ྚG

The display will show 'd' and the LED above P1 switch will flash. 'd' means Default.

ྛG

Press the P1 switch 

ྜG

When the initial default setting is successful, the EFX LITE 6M Audio Controller will automatically restart.

                                      Initial  Default  MIDI  Transmit  Setting                                                Receiving  PC  number  Map

     

Bank/Preset

PC1, PC2

CC1 ~ CC6

CC7/CC8/TAP

CH

NUM

CH

NUM

CH

NUM

Global

PC1:1

PC2:2

61

1

---

CC7:1

CC8:2

TAP:2

CC7:102

CC8:102

TAP:93

1 / 1

1

1 / 2

2

1 / 3

3

1 / 4

4

2 / 1

5

F / 1

57

F / 2

58

F / 3

59

F / 4

60

         

Bank/Preset

PC NUM

Global

61

1 . 1

1

1 . 2

2

1 . 3

3

1 . 4

4

2 / 1

5

F / 1

57

F / 2

58

F / 3

59

F / 4

60

9. Specificati

on

- Buffer Input Impedance    .............

1 M

ȳ

- Buffer Output Impedance

..........

100 

ȳ

- Current Draw    ..........................

150 mA (12VDC Center Negative)

- Dimensions

..............................

300(W) x 82(D) x 55(H) mm

11.8(W) x 3.2(D) x 2.2(H) inches

- Weight    ...................................

750 g / 1.65 lb