M250
Amplifier Instructions for Use Page 2 of 8
Issue 4: May 2002
SAFETY INFORMATION
IMPORTANT!
(U.K. only)
This unit is supplied in the U.K. with a mains lead fitted with a moulded 13 amp plug.
If, for any reason, you need to cut off this plug, please remove the fuse holder and dispose of
the plug safely, out of reach of children.
It must not be plugged into a mains outlet
.
The wires in the mains lead supplied with this appliance are coloured in accordance
with the following code:
Green and yellow..............Earth
Blue...............................Neutral
Brown................................Live
WARNING - This appliance must be earthed
As the colours of the wires of the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured green-and-yellow must be connected to the terminal in the plug
which is marked with the letter E or coloured green or green-and-yellow, or by the earth
symbol:
The wire which is coloured brown must be connected to the terminal which is marked with the
letter L or coloured red.
The wire which is coloured blue must be connected to the terminal which is marked with the
letter N or coloured black.
If connecting to a BS1363 plug, a 13 amp fuse must be used.
WARNING:
The M250 is a powerful amplifier and must necessarily supply high voltages
through the loudspeaker terminals. Therefore, to avoid any possibility of an
electric shock DO NOT TOUCH THE SPEAKER TERMINALS when the unit is
being used.
To comply with BSEN60065 safety regulations, the 4mm “banana” plug holes have
been fitted with plastic blanking pieces. Removal of these will invalidate any elec-
trical safety approval of this product.
WARNING:
Any modifications to this product not expressly approved by Musical Fidelity who
is the party responsible for standards compliance could void the user’s authority to
operate this equipment.