Technical Data
User manual 9000-41011-0200000_hdb_en_20
46 / 92
Fig. 4-13: Temperature derating
Ws System width
∑I Total current
NA Not allowed
4.5.2.2
Mechanical
9000-41011-1000000
Above sea level,
without any restrictions
-500 m ... 2000 m
Above sea level,
max. 8 A trigger current full load per
channel
2000 m ... 4000 m
Above sea level,
max. 6 A trigger current full load per
channel
4000 m ... 6000 m
9000-41011-1600000
Above sea level,
without any restricitons
-500 m ... 4000 m
Above sea level,
max. 12 A trigger current full load
per channel
4000 m ... 6000 m
Variants installation height
Art.-No.
Conditions
Value
Parameter
Conditions
Value
Vibration test
IEC 60068-2-6:2007 Test Fc;
EN 60068-2-6:2008
sin 5 ... 17.8 Hz: 1.6
mm;
17.8 ... 500 Hz: 2.3 g
10x f
Shock test
IEC 60068-2-27:2008 Test Ea;
EN 60068-2-27:2009
1/2 sin 30 g, 11 ms
Shocks caused by rough
handling
(Drop test)
1 m
Содержание Mico Pro fix 1.10