![Murr Elektronik 56 501 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/murr-elektronik/56-501/56-501_manual_1858231022.webp)
Cube67 System Manual
21
V 2.5
Table 3-12 : Overview of MICO variants
Art. No.
Designation
Rated operating branch-circuit current
(full load)
9000-41034-0100400
MICO 4.4 (4 channels)
each 4 A
9000-41034-0100600
MICO 4.6 (4 channels)
each 6 A
9000-41034-0401000
MICO 4.10 (4 channels)
each 10 A
9000-41042-0100400
MICO 2.4 (2 channels)
each 4 A
9000-41042-0100600
MICO 2.6 (2 channels)
each 6 A
9000-41042-0401000
MICO 2.10 (2 channels)
each 10 A
3.2.3
Topology
Fig. 3-2 : Topology
Bus node
Field bus terminal resistance
Field bus line
Compact module
Auxiliary power supply
Expander module
Internal system connection
Terminal resistance of internal system connection
External actuator supply
Sensor/actuator
The bus node has four connections for I/O modules. It is not necessary to set the addresses of the
modules. The modules are actuated automatically in the order of connection. Unused connections are
ignored, i.e. it is possible to connect a module to socket 0, leave socket 1 unused, and connect the next
module to socket 2.
Содержание 56 501
Страница 1: ...Handbuch Manual Manuel Cube67...
Страница 3: ......