Section 80
00-02-0829
2018-02-26
-
55 -
5 Troubleshooting
5.1 Output Does Not Respond
Check the battery or power supply connection.
Check the power supply rating.
•
The PDM switches a high amount of current. Many power supplies are incapable
of sourcing adequate current. Using a battery is the preferred method for
powering the PDM.
Check the CAN bus and messaging.
5.2 PDM Does Not Function
Check the battery or power supply connection.
Check the external circuit breaker or fuse.
Check the power supply connection to the PDM.
•
Verify by connecting a voltmeter to the 5V Sensor Supply and determine if the
unit has power. If the Sensor Supply is not providing 5V, continue to next step.
PDM has been damaged.
•
If the PDM is subjected to an extreme over-current event and has no response,
replace the unit.