45PE-96002B 2 of 2
CONTROL SYSTEMS & SERVICES DIVISION
P.O. Box 1819; Rosenberg, Texas 77471; USA
(281) 342-0297
fax
(281) 341-6006
MURPHY DE MEXICO, S.A. DE C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
+52-444-8206264
fax
+52-444-8206336
www.murphymex.com.mx
FRANK W. MURPHY, LTD.
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+44 1722 410055
fax
+44 1722 410088
www.fwmurphy.co.uk
MURPHY SWITCH OF CALIFORNIA
41343 12th Street West
Palmdale, California 93551-1442; USA
(661) 272-4700
fax
(661) 947-7570
www.murphyswitch.com
In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.
MACQUARRIE CORPORATION
1620 Hume Highway
Campbellfield, Vic 3061; Australia
+61 3 9358-5555
fax
+61 3 9358-5558
FW
Murphy
P.O. Box 470248
Tulsa, Oklahoma 74147 USA
(918) 317-4100
fax
(918) 317-4266
www.fwmurphy.com
R
E
G ISTERE
D
Printed in U.S.A.
Range
Base Model
45PE
45PEF
45PEBP
45PEE
45PEBPE
Specify model number. NOTE: No designator is required for Standard configurations.
List options in alphabetical order (A to Z). Place a dash (–) between each option. See example below.
45PEBP – 4 – S– 100 – EX
BP Voltage (This feature is NOT cover by CSA or the CE mark)
Blank= 120 VAC
2 = 12 VDC
3 = 24 VAC
4 = 24 VDC
Bourdon Tube/Socket
A = Bronze/Brass (/std. < =1,000 psi)
R = Stainless Steel/Steel (std. >= 1,500 psi)
S = Stainless Steel/Stainless Steel
P = K Monel/Monel 400
Vacuum/psi
30” Hg/Vac - 60” Hg/Press.
30” vac - 0 psi
30” vac - 15 psi
30” vac - 30 ps
30” vac - 100 psi
30” vac - 200 psi
30” vac - 300 psi
15 psi
0 - 30 psi
0 - 60 psi
0 - 100 psi
0 - 160 psi
0 - 200 psi
0 - 300 psi
0 - 400 psi
0 - 600 psi
0 - 1000 psi
0 - 1500 psi
0 - 2000 psi
0 - 3000 psi
0 - 5000 psi
0 - 10,000 psi
0 - 20,000 psi
Code
30HV60H
30V
30V15
30V30
30V100
30V200
30V300
15
30
60
100
160
200
300
400
600
1000
1500
2000
3000
5000
10000
20000
kPa/MPa
-101 kPa–203 kPa
-101 kPa - 0 kPa
-101 kPa - 103 kPa
-101 kPa - 207 kPa
-101 kPa - 689 kPa
-101 kPa - 1.38 MPa
-101 kPa - 2.03 MPa
0 - 103 kPa
0 - 207 kPa
0 - 414 kPa
0 - 689 kPa
0 - 1.10 MPa
0 - 1.38 MPa
0 - 2.07 MPa
0 - 2.76 MPa
0 - 4.14 MPa
0 - 6.89 MPa
0 - 10.34 MPa
0 - 13.79 MPa
0 - 20.68 MPa
0 - 34.48 MPa
0 - 68.95 MPa
0 - 137.90 MPa
bar
-1.01–2.03
-1.01 - 0
-1.01 - 1.03
-1.01 - 2.07
-1.01 - 6.89
-1.01 - 13.79
-1.01 - 20.68
0 - 1.03
0 - 2.06
0 - 4.13
0 - 6.89
0 - 11.03
0 - 13.78
0 - 20.68
0 - 27.57
0 - 41.36
0 - 68.95
0 - 103.42
0 - 137.89
0 - 206.84
0 - 344.73
0 - 689.47
0 - 1378.94
Dials:
Dials are dual scale psi and kPa/MPa. Single scale and
custom dials available.
CSA Certified Models:
45PE Series models with
pressure range thru 5000 psig (34.4 MPa) [344 bar] are CSA certi-
fied for Non-Hazardous locations, except options BC, CC, ES, LC
and OS. Explosion-proof “EX” models with pressure range thru
5000 psig (34.4 MPa) [344 bar] are CSA certified for Hazardous
locations. 45PEBP models are not CSA certified.
N.C.–Orange
3
2
1
6
5
4
Common–Yellow
N.O.–Brown
N.C.–Black
LOW SWITCH
HIGH SWITCH
N.O.–Blue
Common–Red
Contact Rating: 2-SPDT snap-switches (one for high and
low pressure); 2 A @ 250 VAC
NOTE: Diagram shows the pointer in the at rest (shelf) position.
45PE Series
Typical Wiring Diagram
How to Order
Options (
NOTE: Not all options available for every model.
)
BC = Back Connected Bourdon Tube (is not CSA certified)
CC = Conduit Connection (is not CSA certified)
ES = Environmentally Sealed, 45PEF only (is not CSA certified)
EX = Explosion-proof (hazardous areas certified up to 5000 psig)
EL = (EXLC) Explosion-Proof Less Case
LC = Less Case (is not CSA certified)
OS = Oil Sealed, 45PEF only (is not CSA certified)
P4 = (PT147) PT147 pressure transmitter w/5 ft. capillary*
P4L = PT147 Less Pulsation Dampener*
*
For capillary greater than 5 ft., specify in 5 ft. increments
following designator, example: P415
P6 = (PT167) PT167 pressure transmitter direct mount
P6S = (PT167SS) PT167 stainless steel