background image

 

00-02-0795 

- 34 - 

10-18-11 

Troubleshooting 

You may see the following messages displayed. Each gives 
you specific information about the engine, ECU, or 
PowerView.  

WAIT TO START PREHEATING  -  The ECU is 
broadcasting a 'Wait to Start' message. Engine 
manufacturers typically recommend against starting the 
engine while the ECU is broadcasting this message. Once 
the ECU stops broadcasting this message, this screen will 
no longer be displayed on the PowerView. 

CANBUS FAILURE  -  The PowerView has not received any 
valid J1939 CAN messages for at least 30 seconds. 

TIMEOUT ECU NOT RESPONDING  -  The PowerView 
sent a request to the ECU for Stored Fault Code (DM2) 
information, and the ECU did not respond to the request. 
This message on the PowerView indicates the ECU may 
not support Stored Fault Code (DM2) functionality over 
J1939. 

 

Содержание PowerView PV-101-A

Страница 1: ...10 18 11 00 02 0795 Section 78 PowerView Model PV 101 A V2 3 User s Guide...

Страница 2: ...ted warranty on materials and workmanship is given with this FW Murphy product A copy of the warranty may be viewed or printed by going to www fwmurphy com support warranty htm BEFORE BEGINNING INSTAL...

Страница 3: ...Transmission Parameters 2 Faceplate Features 3 Navigation and Keypad Functions 4 Operation 9 PowerView Menus First Time Start Up 9 Setting up the Display 12 Main Menu Options 18 Utilities Menu 22 OEM...

Страница 4: ...Set Source Address 28 Restore All Defaults 29 Clear Machine Hours 29 Set Machine Hours 29 Faults and Warnings 31 Troubleshooting 34...

Страница 5: ...ice codes of modern electronic engines and transmissions This guide is intended to help you set up your PowerView display and identify navigation basics and product features The display s simple navig...

Страница 6: ...applicable consult engine or transmission manufacturer for SAE J1939 supported parameters Engine RPM Engine hours System voltage Percent engine load at the current RPM Coolant temperature Oil pressur...

Страница 7: ...00 02 0795 3 10 18 11 Faceplate Features...

Страница 8: ...itches to wear or stick The keys on the keypad perform the following functions Menu Enter or exit menu screens Left Arrow Scroll the screen or move the parameter selection to the left or upward Right...

Страница 9: ...00 02 0795 5 10 18 11 Basic Navigation 1 When Menu is pressed the main menu items are displayed...

Страница 10: ...00 02 0795 6 10 18 11 2 Touching the Arrow Keys will move the selection bar to other menu items...

Страница 11: ...00 02 0795 7 10 18 11 3 Certain menus have multiple pages of items Scrolling past the top item or bottom item on the current page will reveal other menu items on additional pages...

Страница 12: ...lighted by the cursor pressing Enter will select that item and display the corresponding screen 5 Anytime the word NEXT appears above the Arrow Keys there are more screens that may be viewed Use the A...

Страница 13: ...00 02 0795 9 10 18 11 Operation PowerView Menus First Time Start Up 1 When power is first applied to the display the Murphy logo appears...

Страница 14: ...shown Engine manufacturers typically recommend against starting the engine while this message is broadcast from the ECU Once the ECU stops broadcasting this message this screen will no longer be disp...

Страница 15: ...00 02 0795 11 10 18 11 Pressing the Right Arrow Key will display the coolant temperature The screen can be changed to other parameters by pressing Menu...

Страница 16: ...on of the 1 Up display Use Defaults This option contains a set of engine parameters Engine Hours Engine RPM System Voltage Battery Voltage Engine Load at Current RPM Coolant Temperature and Oil Pressu...

Страница 17: ...To select CUSTOM SETUP highlight the option and press Enter A list of engine parameters is displayed 4 To select a parameter use the Arrow Keys to scroll and highlight the parameter then touch Enter S...

Страница 18: ...eturn to the CUSTOM SETUP menu 7 Selecting the AUTOMATIC SCAN ON function will cause the 1 up display to scroll through the selected set of parameters one at a time 8 Once the USE DEFAULTS CUSTOM SETU...

Страница 19: ...th parameters you define for each quadrant 1 Touch Menu and use the Arrow Keys to highlight SETUP 4 UP DISPLAY then press Enter 2 To select USE DEFAULTS highlight the option and press Enter A message...

Страница 20: ...umber to the right of the parameter indicates the quadrant in which it is displayed 1 upper left quadrant 2 lower left quadrant 3 upper right quadrant 4 lower right quadrant 6 Use the Arrow Keys to hi...

Страница 21: ...00 02 0795 17 10 18 11 8 The parameter in the selected quadrant has changed to the parameter selected in the previous screen 9 Repeat the parameter selection process until all spaces are filled...

Страница 22: ...nguage From LANGUAGES you may select ENGLISH ESPANOL FRANCAIS ITALIANO or DEUTSCH The currently selected language is indicated by an asterisk Stored Fault Codes Select this and PowerView requests and...

Страница 23: ...re internal reminders within PowerView Once a Service Reminder is active warnings will show SPN 916 and FMI 17 Check PowerView Service Reminders prior to calling Technical Support 1 Use the Arrow Keys...

Страница 24: ...ify and touch Enter 6 The Reminder name appears at top screen The hour value displays mid screen and allows you to set the number of hours to elapse before a Reminder prompts Bottom screen shows Cance...

Страница 25: ...d touch Menu to return to the Main Menu Select Units From SELECT UNITS you may select how information is displayed ENGLISH for Imperial units PSI F METRIC KPA METRIC BAR for IS units kPa Bar C Backlig...

Страница 26: ...configuration Gage Data View information for optional connected PVA gages Remove All Gages Reset the gage memory on the PowerView Software Version This screen lists Configuration Firmware Languages a...

Страница 27: ...ouch Enter to toggle between master and slave 3 Select SERIAL PORT SETUP slave mode only then touch Enter 4 Continue to scroll each selection BAUD RATE PARITY DATA BITS and STOP BITS to configure the...

Страница 28: ...lt change to a different J1939 Version If the fault SPN does not change when the version is changed the ECU generating the fault is using Fault Conversion method 4 If the SPN number does change but is...

Страница 29: ...eft Arrow Key to decrease the percentage of remaining fuel at which to send a warning The default is 20 NOTE The PowerView accepts optional Murphy fuel sender recommend Model ES2F for fuel level infor...

Страница 30: ...eric spaces provided Start at the furthest left numeric value and use the Left Arrow Key to increment the number and the Right Arrow Key to move to the next numeric position The following items are in...

Страница 31: ...rough the Serial Port Setup list and make selections for BAUD RATE PARITY DATA BITS and STOP BITS to configure the serial port parameters for your Modbus slave application CANBUS Data Rate Touch Enter...

Страница 32: ...uch the Arrow Keys to scroll through the selections 0 253 and ALL 3 Once the target address displays touch Enter 4 A confirmation screen displays selecting NO Menu returns to the SELECT ENGINE ECU scr...

Страница 33: ...FACTORY DEFAULTS displays when this is selected Clear Machine Hours Use this to clear machine hours internal to PowerView outside of ECU hours Set Machine Hours Machine hours calculate internally whe...

Страница 34: ...tpoints Clear Fuel Setpoints or choose to set the fuel setpoints for and fuel tank levels Fuel Setpoints must be ON to work with a non Murphy fuel sender Modifying fuel setpoints is a complex process...

Страница 35: ...rnings The PowerView provides two means for detecting faults and warnings visual LEDs on the casing See Faceplate Features and fault indicators on the display Visual Indication Amber LED Warning Red L...

Страница 36: ...ONDING NOTE The fault can only be cleared by correcting the cause of the fault condition Active Fault Codes When the PowerView receives a fault code from an engine the 1 up or 4 up display will be rep...

Страница 37: ...nd return to the 1 up or 4 up display touch Enter The display will return to the 1 up or 4 up display but the display will contain the shutdown icon 2 Touch Enter to redisplay the hidden fault Touch E...

Страница 38: ...le the ECU is broadcasting this message Once the ECU stops broadcasting this message this screen will no longer be displayed on the PowerView CANBUS FAILURE The PowerView has not received any valid J1...

Страница 39: ...place of a parameter value NO DATA The PowerView has not received data for the selected parameter for at least 5 seconds NOT SUPPORTED The ECU is sending a message that it does not support this param...

Страница 40: ...adrants is empty No parameter has been selected for display in this quadrant Display is not readable either very dim or very dark The LCD contrast may have been over or under adjusted Press and hold t...

Страница 41: ...00 02 0795 37 10 18 11 NOTES...

Страница 42: ...This document including textual matter and illustrations is copyright protected by Murphy Industries Inc with all rights reserved 2011 Murphy Industries LLC Other third party product or trade names re...

Отзывы: