Specifications 

Interface 

Display

:   

Monochrome HR-TFT with backlight 

2.7” / 68 mm, WQVGA (400 x 240 pixels) 

Languages:

  

English, Spanish, German, French, Italian 

(3) LEDs

:  Green (mode), Yellow (warning) and Red (shutdown) 

Operator Controls

(11) Raised silicone keypads, tactile feedback 

(1) Rotary key switch, power on/off 

(1) Push switch (red), engine stop 

Power Supply 

Operating Voltage

: 8-32 VDC, reverse battery polarity and load-dump protected 

Cranking Power Holdup:

  0 VDC up to 50mS (also good for brownout / blackout 

instances) 

Current Consumption

:   

Power on in stopped state; 117 mA at 12 VDC. 

Power on in standby mode; 52 mA at 12 VDC 

Inputs (9) 

(5) Digital:  

configurable (active on High, Low, Open) 

(3) Analog:

  configurable (4-20 mA, 0-5V, resistive or digital ground) 

(1) Frequency:  

supporting: 

Magnetic Pickup (30 Hz – 10 kHz, 2.0 VAC – 120 VAC) and 

Engine Alternator (30 Hz – 10 kHz, 4.5 VRMS – 90 VRMS) 

Outputs (8) 

(2) Relay:  

swDC, 10A 

(1) Relay:  

Form C (dry / volt-free), 10A 

(2) Low-side FET:  

(-DC), 1A 

(2) High-side FET:  

(+DC), 1A 

(1) Dedicated Alternator Excitation:

  +DC, 1A 

Communications 

(1) CAN:  

J1939 

(1) RS485:  

Modbus RTU

 

Mating Connectors 

21 Position, Deutsch HDP26-24-21SE 

31 Position, Deutsch HDP26-24-31SE 

Physical / Environmental 

Enclosure material:  

Polycarbonate 

Dimensions (WxHxD):  

9.59 x 7.34 x 5.20 in. (243.48 x 186.5 x 132.23 mm) 

Weight:

  4 lbs (1.8 kg) 

IP Rating:

 IP67 

Operating and Storage Temperature:  

-40° to +85° C (-40° to 185° F) 

Vibration:  

7.86 G

rms

 (5-2000 Hz), 3-axes random  

Shock:

 ±50G, 3-axes

 

Содержание PowerCore TEC-10

Страница 1: ...02 23 Section 30 PowerCore Model TEC 10 Installation Manual Products covered in this document comply with European Council electromagnetic compatibility directive 2014 30 EU and electrical safety dire...

Страница 2: ...g but not limited to double insulation and fire containment Observe all Warnings and Cautions in each section of these instructions The TEC 10 is designed for use in industrial environments for monito...

Страница 3: ...lation 2 Inspecting Package Contents 2 Tools Needed 2 Installation 3 Dimensions for Installation 4 PIN Specifications 6 Accessories 7 Specifications 8 Interface 8 Power Supply 8 Inputs 9 8 Outputs 8 8...

Страница 4: ...oximity to the machine s being controlled as they may commence operation suddenly and without warning LENS CLEANING PROCEDURES The lens on the TEC 10 is composed of Polycarbonate materials Use only mi...

Страница 5: ...ation Inspecting Package Contents Before attempting to install the product it is recommended that you ensure all parts are accounted for and inspect each item for damage which sometimes occurs during...

Страница 6: ...the location is subject to investigation by the local authority having jurisdiction at the time of the installation Recommended torque for tightening both the shockmounts into the panel and the nuts o...

Страница 7: ...Section 30 00 02 0977 2018 02 23 4 Dimensions for Installation Front Inches mm Side View...

Страница 8: ...Section 30 00 02 0977 2018 02 23 5 Back View...

Страница 9: ...hrottle Decrease 15 Unavailable S Digital Output 4 DC 1A Default Setting Throttle Increase 16 Unavailable T Frequency Input 17 Relay 3 Common RLY 3 Defaulted to Not Used 10A Max U J1939 CAN Low includ...

Страница 10: ...ip Harness 3m approx 40000479 Deutsch Connector Kit 21 pin and 31 pin Panel Connector Kit 40000531 Deutsch Connector Kit 21 pin Panel Connector Kit Engine Only 78700046 Deutsch Connector Kit 31 pin Pa...

Страница 11: ...e 52 mA at 12 VDC Inputs 9 5 Digital configurable active on High Low Open 3 Analog configurable 4 20 mA 0 5V resistive or digital ground 1 Frequency supporting Magnetic Pickup 30 Hz 10 kHz 2 0 VAC 120...

Страница 12: ......

Отзывы: