Section 15
00-02-0423
08-12-09
- 1 -
General Information
Description
The Murphy LM2000 model maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the
correct running-oil-level, the LM2000 will replenish oil as it is used. An integral, low-level switch will alarm and/or
shutdown the equipment if supply oil is lost and the equipment continues to use oil.
Dimensions
Operating Range of the Snap-Switch
Figure 1
shows the LM2000 dial and the operating
range of the switch. If level is within the designated
zones the switch will activate.
The switch activates approximately 1/4 in. (6 mm) from
the bottom of the low zone. The dial in
Figure 1
shows
that if level continues to drop into the low-low zone, a
shutdown will occur.
Figure 1
NOTE:
Color zones on dial face show approximate normal operating zones. Actual
conditions may vary depending upon operating characteristics of the engine. Placement
of the LM2000 according to the above instructions will compensate for these conditions.