Operation 

At each power up, FuelCAN checks all three inputs for  

an in-range sender resistance. If more than one sender is 

connected at power-up, FuelCAN prioritises input selection  

in the order 1 (Murphy), 2 then 3. 
Once FuelCAN has selected a valid input, it continues to  

use that input until the DC power supply is cycled. FuelCAN 

transmits fuel level data every 2 seconds. Data specification  

is otherwise as SAE J1939-71: 

PGN  65276 (00FEFC

16

Message data length  8 bytes 

Relevant byte  #2 (fuel level) 

Data page  0 

PDU format  254 

PDU specific  252 

Resolution  0.4%/bit gain, 0% offset 

Data range   0 to 100% 

If a sender failure (short or open circuit) occurs during 

operation, FuelCAN transmits fuel level data of value  

0xFE

16

 (indicating ‘measurement error’). 

If no valid sender is detected at power-up, FuelCAN transmits 

a value 0xFF

16

 (indicating ‘measurement not available’) and 

flashes its LED in a ‘heartbeat’ pattern (two short pulses, 

followed by a longer pause). J1939 message PGN65275  

also includes bytes for other parameters, including washer 

fluid level (byte #1), fuel filter differential pressure (byte #3), 

engine oil filter differential pressure (byte #4) and cargo 

ambient temperature (bytes #5/6). For each of these 

parameters, FuelCAN transmits a value 0xFF

16

 (indicating 

‘measurement not available’). 
LED operation is as follows:- 

LED pattern 

Status 

 f

f

o

 r

e

w

o

P

 f

f

O
Flashing 

(‘heartbeat’ pulse on) 

Power on, but all inputs open circuit 

(valid sender not detected). 

Flashing 

(50/50% on/off) 

Power on, valid sender input, but no 

CAN activity. 

  

d

n

a

 t

u

p

n

r

e

d

n

e

s

 

d

il

a

v

 ,

n

o

 r

e

w

o

P

 

n

O

CAN activity 

Maintenance and Warranty 

FuelCAN contains no user-serviceable parts. Maintenance is 

therefore limited to the following preventative checks: 

  Check that FuelCAN electrical connections are secure. 

  Check that the case is mounted securely, with vibration 

and environmental exposure minimised where possible. 

The case may be wiped with a clean, damp cloth. Do not 

use cleaning solvents. 

FuelCAN is supplied with a two year warranty on parts and 

workmanship. In the event of a fault or technical query,  

and before returning equipment, please contact your  

Murphy representative for technical support.

  

Electrical Connection & Mounting 

Electrical Connection 

FuelCAN connection is via 8 colour-coded flying leads  

(see diagram on page 1). 

RED: Power supply positive DC 

BLACK: Power supply negative DC 

Connect these wires to a smooth DC power supply in the range 

7 to 35 VDC. A 1 Amp anti-surge fuse is recommended in the 

positive DC line.

 

FuelCAN operates with negative earth/ground or fully insulated 

DC systems. 

DO NOT

 use FuelCAN with positive earth/ground 

systems. 

 

YELLOW: CANbus high 

GREEN: CANbus low 

Connect these wires to the engine’s CANbus, using the 

appropriate twisted-pair cable to J1939 specification. FuelCAN 

includes a non-removable 120 Ohm terminating resistor. 

BLACK: Sender common (negative DC) 

VIOLET: Sender input 1 (Murphy)

 

ORANGE: Sender input 2

 

WHITE: Sender input 3

 

For best measurement accuracy, use an insulated return  

(2-wire) resistive fuel level sender, e.g. (for input 1) Murphy 

ES2F series. Connect one sender terminal to the appropriate 

FuelCAN input lead (1, 2 or 3); connect the other sender 

terminal to FuelCAN’s Sender Common (black) wire. 
Where a 1-wire (negative DC/ground return) sender is used, 

connect the black (sender common) wire to battery negative. 

Mounting 

FuelCAN uses an epoxy-resin filled, polycarbonate case for high 

impact and environmental resistance. The case is compact  

and light enough for inclusion in (or tie-wrapping to) an engine 

wiring harness; or, using the actual product as a template, 

FuelCAN can be surface mounted via four M4 (0.15 in) holes 

(see diagram on page 1 for approximate dimensions). The case 

is sealed to IP65; the exposed flying leads must use connectors 

appropriate for the environmental sealing required. 