background image

 ELD series

EARTH LEAKAGE DETECTOR UNITS

A range of versatile and economical earth leakage
detection relays. Each unit is housed in a robust, glass
filled nylon case: an aperture in the casing allows the
installation cabling to be passed through the integral
core balance transformer.

The electronic circuitry combines a stable amplification
of the transformer output with an ability to give high
sensitivity and fast operating speeds. Detection of an
earth fault results in the energisation and latching of the
unit's SPCO relay. The unit is reset by momentarily
removing the auxiliary supply.

Protection from excessive fault current and supply
transients are fitted as standard, as is filtering to allow use
with chopped waveform and variable drive applications.
A 'test' facility is supplied in the form of a button, either
pre-fitted into the unit's front facia or connected remotely.

Electrical connection on standard units is by a colour coded,
6 way flying lead, with terminal blocks available as an
option. Each unit may be mounted on a front panel or back-
plate using two 3mm threaded inserts; an optional mounting
assembly (part no. EMA) is also available for front access
back-plate mounting.

Standard units include:

ELD2

Basic unit, with 20mS typical trip time.
Fast response to earth leakage faults.

ELD4

As ELD2, but with longer trip delays, 80mS
to 5 secs. Prevents nuisance tripping in motor
protection circuits and allows time discrimination
in distribution networks.

ELD5

As ELD4, but with an adjustable trip delay.
Available in various time ranges up to 2 seconds.

With options:–

'VS'

Adjustable trip current (via front facia potentiometer.)

'HT'

High temperature specification (to +60

°

C ambient).

'TB'

Screw terminal connectors instead of flying leads.

'RC'

Special calibration and 1m wiring for use with
      remote CTs (for RTCs of >125mA).

Variations on our standard units and options are also
available: please call with your requirements.

When ordering, please specify:–

a) Product type number (ELD2, ELD5, etc.)
b) Auxiliary supply voltage
c) Trip current (fixed, or variable range for VS option)
d) System frequency (50, 60 or 400 Hz.)
e) Trip delay time (fixed or variable, according to model)
f) Additional options, if required.

Accessories:–

EMA

Mounting assembly for ELD series.

Remote CTs

A range of remote core balance/current
transformers, enabling specially
calibrated ELD units to be used with
larger cables. Available in a range of
sizes, with or without a magnetic screen
(see sheet M060101 for full details).

The Generator Controls Division of 

R

M060501

Issue 4, revised 09/98

Catalogue section 75

Since 1939

Frank W. Murphy Manufacturer

PO Box 470248, Tulsa, Oklahoma 74147, USA

Tel: + 1 918 627 3550  Fax:  + 1 918 664 6146

email: [email protected]

web: http://www.fwmurphy.com

Frank W. Murphy Southern Division

PO Box 1819, Rosenberg, Texas 77471, USA

Tel: + 1 281 342 0297   Fax: + 1 281 341 6006

email: [email protected]

Frank W. Murphy Ltd.

   Incorporating

 

Modex Automation

Church Road, Laverstock, Salisbury U.K.

Tel: + 44 1722 410055  Fax + 44 1722 410088

Pour service en Français, tél: + 44 1722 410697

email: [email protected]

web: http://www.fwmurphy.co.uk

Murphek Pty. Ltd.

1620 Hume Highway, Campbellfield, Vic. 3061 Australia

Tel: + 61 3 9358 5555   Fax: + 61 3 9358 5558

email: [email protected]

Murphy Switch of California

PO Box 900788, Palmdale, California 93590, USA

Tel: + 1 805 272 4700   Fax: + 1 805 947 7570

email: [email protected]

web: http://www.murphyswitch.com

Murphy de Mexico S.A. de C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje

San Luis Potosí, S.L.P. México 78384

Tel: + 52 48 206264  Fax: + 52 48 206336

email: [email protected]

Frank W. Murphy Pte, Ltd.

No. 2 Tuas South Street 2, Sprintecs Building

02-01/02, Singapore 637895

Tel: + 65 863 1398    Fax:  + 65 863 0208

email: [email protected]

Frank W. Murphy Ltd. en France

Tel: +33 (1) 30 76 26 26 Fax: +33 (1) 30 76 39 89

Direct usine Tel: + 44 1722 410697

email: [email protected]

 Dimensions (mm)

31

4

3

25

25

EMA

ELD

162

136

176

148

59

Connection (standard unit)

RED

L1

External

Test

Button

BLUE

BLACK

L2 or N

Test

ELD

GREEN

WHITE

YELLOW

Product Specification

Power supply:

operating voltages (ranges)

            

 (all for 50/60Hz.)

110V AC (100 – 120 V)

230 V AC (200 – 250 V)

415 V AC (380 – 440 V)

power consumption

< 100mA

Control:

trip levels

fixed and variable, 10mA to 30A

trip point accuracy

to BS4293

Relay output:

(ratings for resistive load)

SPCO contacts, rated

3A @ 250V AC/30V DC,

1A @ 440V AC

Physical:

operating temperature

standard unit: –25 to +40

°

C

'HT' spec.: –25 to +60

°

C

weight (with EMA)

approx. 330 g