Murdock H2O To Go BF15 Series Скачать руководство пользователя страница 9

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

Surface Mounted Bottle Fillers

 

7020-957-001

Revised: 08/02/19

Page 9 of 13

2. Connect the Sensor Wires to either the Solenoid Valve or -BCD Bottle Counter Display (if equipped). 

ELECTRICAL INSTALLATION:

1A. Plug-In Operation: Plug transformer provided into GFCI protected electrical service, used by the Bottle Filler. 

START UP:

NOTE: PLUG-IN POWER IS A STANDARD FEATURE FOR BF16.

BOTTLE COUNTER ADJUSTING & RESETTING INSTRUCTIONS:

1. Air within the Bottle Filler System or the structure supply piping will cause an irregular Spout outlet stream until 

purged out by incoming water. Hold cup (or similar object) directly below Filler Spout is recommended when first 
activating Bottle Filler to prevent excessive splashing. Activate sensor until steady water stream is achieved.

NOTE: Bottle Counter Has Multiple Functions

Reset/ Mode Button
• Counts refilled bottles
• Adjustable for units with and without Filters
• “REPLACEMENT FILTER” alert function
• Alert reset, when Filter is replaced

Description

Illuminated LCD Display counts bottles and has a Filter replacement alert function.

 

OPERATING INSTRUCTIONS: 

Bottle Counting Function

The software applies a flow volume of approximately 16.9 fl oz (volume in standard size plastic water bottle) to 
each bottle counted. If the flow volume is less than 16.9 fl oz, there will be no count but the volume will 
accumulate, so that part way through the next cycle the total bottle count will change.

Position container to be filled directly in front of the Sensor and centered under the Filler Spout. Water flow starts 

automatically. When the container is almost filled, remove container. The water will stop flowing.

Fill Spout

Sensor

-BCD Bottle Counter Display
with Illuminated Display

Содержание H2O To Go BF15 Series

Страница 1: ...ing fountain or Murdock s limited warranty is void Murdock warrants that its products are free from defects in material or workmanship under normal use and service for a period of one year from date of shipment from the factory Murdocks s liability under this warranty shall be discharged solely by repair or replacement of defective material provided Murdock is notified in writing within the time p...

Страница 2: ...re absorbing devices will be installed as close as possible to the quick closing valve Electrical Receptacle s must be wired to a GFCI protected circuit Fixture must be earth grounded per N E C National Electrical Code Important Some options may slightly alter installation To ensure proper installation review the manual thoroughly and verify rough ins before beginning any work File this Manual wit...

Страница 3: ... location for later use Open unit by swinging Mounting Panel down 1 10 32 x 1 Allen Button Head Screw 1 Bottle Filler Housing 2 Mounting Panel 3 Remove Bottle Filler Housing from unit by removing one Screw from the Hinge and sliding the Bottle Filler Housing out Set aside for later use in the Manual Mounting Panel 2 10 32 x 3 4 Phillips Round Head Screw 3 Bottle Filler Housing 1 2 Finished Wall 1 ...

Страница 4: ... rough and Waste outlet for 1 1 2 P Trap Use Mounting Panel as template General Notes 1 Dimension indicated with is for 34 1 2 deck height Adjust accordingly for preferred deck height 2 Anchoring is required for holes marked with X Auxiliary holes available if required 4 2 C L 241 4 TYP A F F 12 TYP 91 2 TYP 47 8 TYP 33 4 TYP 7 261 4 A F F 61 4 31 2 4 277 8 A F F 3 1 4 5 110VAC Electrical Duplex 1...

Страница 5: ... secured to finished wall install P Trap Waste Outlet P Trap must not extend more than 4 1 4 from finished wall Mounting Panel 1 P Trap 2 Drain Tray 3 Connect 3 8 O D Y Strainer to main water supply Recommend using angle stop for easy maintenance Angle stop must not extend more than 3 1 2 from finished wall Angle Stop Recommended 2 Y Strainer 3 Mounting Panel 1 Re mount Bottle Filler Housing by re...

Страница 6: ...Line 3 Valve Water Supply Outlet Elbow 3 Bottle Filler Water Supply Inlet Tubing 4 1 2 4 3 Valve Air Line Inlet 4 Plastic Cable Holder 5 With Bottle Filler Housing secured to unit connect water supply line Keep supply line within plastic cable holders to prevent supply line from getting pinched or damaged If Fixture is BF16 see steps 8B 9B 8A 9A With Water Supply Line properly secured connect 1 8 ...

Страница 7: ...electrical wiring as shown below Keep supply line and wiring within plastic cable holders to prevent supply line and wiring from getting pinched or damaged If fixture is BF15 see steps 8A 8B Mounting Panel 1 Bottle Filler Housing 2 Solenoid Valve Electrical Wiring 3 Plug in power supply turn on water and check for leaks throughout the system Mounting Panel 1 Bottle Filler Housing 2 Power Supply 3 ...

Страница 8: ...ller Housing 1 Lanyard 2 Mounting Panel 3 10 32 x 1 Allen Button Head Screw 2 Bottle Filler Housing 3 Bottle Filler Assembly 1 1 Lift up from Fill Spout area to close the unit by swinging Bottle Filler Housing up and secure with Screws from step 1 Do not force closed Address any interference if necessary Do not over tighten 11 To open unit for maintenance purposes remove Top Screws Lift Bottle Fil...

Страница 9: ...en first activating Bottle Filler to prevent excessive splashing Activate sensor until steady water stream is achieved NOTE Bottle Counter Has Multiple Functions Reset Mode Button Counts refilled bottles Adjustable for units with and without Filters REPLACEMENT FILTER alert function Alert reset when Filter is replaced Description Illuminated LCD Display counts bottles and has a Filter replacement ...

Страница 10: ...the mode settings The Reset Mode Selection Button is accessible by removing the Housing then locate the large hole in the back of the Display Mounting Bracket Use your finger or nonconductive object to depress the Reset Mode Selection Button CAUTION DO NOT USE SHARP OR METAL OBJECTS With this Reset Mode Button you are able to indicate whether the unit has a Filter or does not have a Filter The Res...

Страница 11: ...the site to ensure there are no leaks DISCONNECTING THE TUBE Prior to disconnecting the Tube from the Fitting ensure that the water line is depressurized Push Collet Square towards the Push In Fitting Body and hold While holding the Collet in pull on the PE Tubing to remove from the Push In Fitting TO CUT TUBE Cut to fit length of 1 4 PE Tubing and remove any burrs or sharp edges Ensure that the o...

Страница 12: ...T NUMBER DESCRIPTION 1 7014 271 002 WALL MOUNTED FRAME ASSY BF15 16 7 7012 055 000 FOAM PIPE INSULATION 2 CONTACT FACTORY HOUSING ASSEMBLY BF16 BCD 8 1895 709 000 ELBOW 1 4 PUSH IN X 1 4 STEM 3 4970 265 000 P TRAP 9 2150 005 199 1 8 O D LLDPE TUBING CLEAR 4 0116 123 000 10 32 x 1 BUTTON HEAD SCREW 10 2566 160 001 PBH S T SIDE OUTLET PUSHBUTTON 5 7000 021 001 Y STRAINER 11 7001 203 001 AIR TROL VAL...

Страница 13: ...16 123 000 10 32 x 1 BUTTON HEAD SCREW 2 7014 270 001 HOUSING ASSEMBLY BF16 BCD 10 7000 021 001 Y STRAINER 3 4970 265 000 P TRAP 11 2169 000 000 1 4 O D LLDPE TUBING BLUE 4 2563 381 001 SENSOR A ASSEMBLY 12 7012 055 000 FOAM PIPE INSULATION 5 0110 012 000 6 x 3 16 TRUSS HEAD SCREW 13 7001 200 001 SOLENOID VALVE MOUNTING ASSY 6 0716 111 001 BOTTLE COUNTER WITH CONNECTORS 14 0710 731 001 POWER SUPPL...

Отзывы: