,MAINTENANCE:

v

To  remove  pushbutton  assembly

  remove  bowl  from 

housing.  From  inside  of  the  housing,  remove  inlet  and 
outlet  lines  from  push-in  ports  of  valve  body.  Using  a 
spanner wrench remove pushbutton and retaining ring.

v

To  access  bubbler

,  remove  bowl  from  housing 

assembly.  Remove  bubbler  plug  with  a  spanner  wrench 
and remove nut holding bubbler in place.

v

To  replace  regulator

,  use  a  spanner  wrench  to 

remove  pushbutton  and  retaining  ring  from  the  flange 
collar. Use a spanner wrench to remove retainer from the 
inside  of  the  flange  collar.  Remove  regulator,  insert  new 
regulator  and  align  ports  to  new  regulator  with  mating 
ports of valve body then replace retaining ring.

v

Re-assemble  in  reverse  order

.  When  replacing  inlet 

and outlet lines, ensure to insert supply line into valve port 
labeled  “IN”.  Ensure  plastic  lines  are  not  kinked  when 
fountain is reassembled.

All normal maintenance is done from above ground.

v

Protect  exposed  valve  assembly,  tubing  and  tube 

openings  to  prevent  damage  to  equipment  or  to  prevent 
tubes from becoming filled with soil or debris.

v

Always  shut  off  water  supply  when  doing  any 

maintenance.

FLOW ADJUSTMENT

Ø3/16"

Hole

Slotted 
Screwdriver

Increase 

Flow

Decrease 

Flow

GRT75-PF AND GRT75-PF-RFS MAINTENANCE:

REGULATOR 

VALVE BODY

FLOW REGULATOR 

CARTRIDGE

VALVE RETAINING 
NUT

BRASS RETAINER 
RING

PUSHBUTTON

FIBER RING

RUBBER GASKET

Содержание GRT75-PF Series

Страница 1: ...which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the rep...

Страница 2: ...ng screw at center of drain and separate from fixture housing See DETAIL A 2 Use dimensional information below or use fixture as a template to locate and mark floor and wall anchoring Floor anchors are provided Wall anchors are provided by the installer Do not fix to wall and floor at this time 3 Stub out 1 1 4 Wall Waste outlet extending waste tube 3 3 4 minimum Align waste tube with elbow compre...

Страница 3: ...fountain spreading and compacting gravel as necessary Prepare form approximately 6 diameter to protect supply and waste stub outs NOTE Refer to local codes for sufficient concrete pad depth height l It is recommended to include a supply stop appropriately located on the supply line l Prepare trench for water supply line and waste line if required At fountain location prepare hole to trench depth a...

Страница 4: ...the flange collar Use a spanner wrench to remove retainer from the inside of the flange collar Remove regulator insert new regulator and align ports to new regulator with mating ports of valve body then replace retaining ring v Re assemble in reverse order When replacing inlet and outlet lines ensure to insert supply line into valve port labeled IN Ensure plastic lines are not kinked when fountain...

Страница 5: ...5 0431 222 000 RUBBER GASKET 6 1895 451 000 1 4 OD NYLON NUT W PLASTIC GRIPPER 7 7000 006 000 FLAT DRAIN ADAPTER GASKET 8 7000 012 000 SOLID BUBBLER S S 9 7000 017 001 ELBOW ORING x 1 1 4 GRT75 PF RFS ONLY 10 7000 021 001 Y STRAINER 1 4 NPT x 3 8 OD COPPER 11 7000 050 000 REGULATOR VALVE BODY 12 7000 051 000 RETAINING NUT VALVE 13 7000 053 199 JAM NUT 1 1 4 14 7000 060 000 FLOW REGULATOR CARTRIDGE...

Страница 6: ... connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or ...

Страница 7: ...tridge 1 1 Check water main supply open 1 3 Inspect in line strainer for debris clean 1 2 Inspect stop by others open no debris 2 1 For push pad activated drinking fountains only Open fixture and move valve bracket assembly further back from push pad 2 2 Replace valve cartridge 3 3 Inspect stop by others open no debris 3 1 Adjust the valve flow rate See appropriate fixture installation instructions 3...

Отзывы: