MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
Please visit
www.murdock.com
for most current specifications.
Allow concrete to cure before completing installation.
Remove basin from pedestal and set aside. Align
anchoring studs to pedestal mounting holes and secure
pedestal to slab. To ensure plumb installation, lay a bubble
level on fountain bowl and adjust using shims or washers
until unit is level.
Make up connections to 3/8" OD (1/4" nominal) x 4" long
copper tube with inline Y-strainer. Make up waste
connection to 1-1/4" OD tailpiece provided.
Turn on water supply and test operation of bubbler by
depressing button and adjust flow rate as required. Check
all connections for leaks.
Turn on water supply and test for proper operation and
checking for leaks.
FYI:
Protect exposed valve assembly, tubing and tube
openings to prevent damage to equipment or to prevent
tubes from becoming filled with soil or debris.
Rough-in water supply for 3/8" OD (1/4" nominal) x 4" long
copper tube connected to inline Y-strainer inlet provided. A
supply stop by others is recommended.
Test operation of bubbler by depressing button and adjust
flow rate as required. Check all connections for leaks.
All normal maintenance is done from above ground.
v
Always shut off water supply when doing any
maintenance.
v
To remove pushbutton assembly
remove bowl
from housing. From inside of the housing, remove
inlet and outlet lines from push-in ports of valve
body. Using a spanner wrench remove pushbutton
and retaining ring.
v
To replace regulator
, use a spanner wrench to
remove pushbutton and retaining ring from the
flange collar. Use a spanner wrench to remove
retainer from the inside of the flange collar. Remove
regulator, insert new regulator and align ports to new
regulator with mating ports of valve body then
replace retaining ring.
v
To access bubbler
, remove bowl from housing
assembly. Remove bubbler plug with a spanner
wrench and remove nut holding bubbler in place.
v
Re-assemble in reverse order
. When replacing
inlet and outlet lines, ensure to insert supply line into
valve port labeled “IN”. Ensure plastic lines are not
kinked when fountain is reassembled.
WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY DRINKING FOUNTAINS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
Valve Body w/
Flange Collar
Brass Nut
Regulator
Retainer
Fiber Ring
Rubber Gasket
Retaining
Ring
Pushbutton
1/4" Push-In
Elbows
Page 2 of 3
9938-159-M01
07/21/14
INCREASE
FLOW
DECREASE
FLOW
Ø3/16"
HOLE
SLOTTED
SCREWDRIVER
FLOW ADJUSTMENT