background image

 

provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of 
the valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-
absorbing devices will be installed as close as possible to the quick closing valve.

INSTALLATION:

1.   Mount hanger bracket to wall horizontally level as shown in Roughing-In and Dimensional Drawing. 

Note: Adjust height of bracket if bubbler outlet height is required to vary from that shown.         Hanger 
Bracket MUST be securely anchored to wall fasteners sufficient to support 3 times weight of cooler. If 
wall can not provide adequate support, order and install optional fixture support carrier. 

2.   Remove the access panel from the drinking fountain and set aside in a safe place. Save the screws in a 

secure location for re-use in later stages of installation.

3.   Hang the drinking fountain on the hanger bracket, ensuring the bracket tabs engage AND seat in the 

slots in the back of the drinking fountain. Verify drinking fountain is level, left to right AND front to back 
from bottom of unit. NOTE: The bubbler stream may be adversely affected if unit is not square and level. 
Bottom of unit and louvers should be used as reference to verify unit is square and plumb. 

4.   Anchor drinking fountain to wall at other mounting points in base. Shim lower rear mounting points to 

level unit if necessary. 

5.   Thoroughly flush the 3/8” O.D. supply line and then connect drinking fountain to water supply angle stop 

valve (by others) with supplied 3/8” O.D. copper tube. 

6.   Make up 1-1/4” O.D. p-trap (by others) waste connection.

START UP:

1.   Before assembling access panel to drinking fountain, but after thoroughly flushing the supply line and 

connecting it to the fixture, turn on building water supply and check all connections for leaks.

2.   Air within the d

  rinking fountain system or the structure supply piping will cause an irregular bubbler 

outlet stream until purged out by incoming water. Covering the bubbler with a clean cup (or similar 
object) is recommended when first activating drinking fountain to prevent excessive splashing. Depress 
the pushbutton until steady water stream is achieved.

3.   If water flow requires adjustment, insert a slotted narrow blade screwdriver in the hole centered on the 

underside of the fixture in the knee clearance area up to the flow regulator. Turning clockwise will 
increase flow and turning counterclockwise will decrease flow.

4.   Recheck all water and drain connections with water flowing through system.

5.   Assemble access panel to drinking fountain with screws furnished.

CLEANING & MAINTENANCE GUIDE:

1. Periodically remove and clean out auto stop strainer.

2. Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the Acorn 

warranty.

3. Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra  care must 

be used cleaning chrome plated items and mirror finished stainless steel. They can scratch easily and 
should only be cleaned using a clean, soft cloth and mild soap with water or a mild glass cleaner. 

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A172FGVR

Page 4 of 10

New: 

08/01/16

7020-930-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Содержание A172-FG-VR-WF1

Страница 1: ...cover installation or labor charges and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direc...

Страница 2: ... 333 2543 Fax 626 855 4860 www murdockmfg com Member of I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 ALLOW 4 INCHES 102 MM MINIMUM CLEARANCE PER SIDE FOR VENTILATION 3 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HE...

Страница 3: ...ult 5 All burrs must be removed from outside of cut tubes before inserting into coupler or other components 6 Warranty is voided if installation is not made following current Acorn Engineering installation instructions and if components are assembled to the fixture that is not approved by Acorn Engineering 7 Fixture operates within water pressure range of 20 to 105 psig Acorn Engineering will not ...

Страница 4: ...g access panel to drinking fountain but after thoroughly flushing the supply line and connecting it to the fixture turn on building water supply and check all connections for leaks 2 Air within the drinking fountain system or the structure supply piping will cause an irregular bubbler outlet stream until purged out by incoming water Covering the bubbler with a clean cup or similar object is recomm...

Страница 5: ... fully seated onto button 7 Reinstall strainer 4 and plug 3 using maintenance tool 5 NOTE STRAINER FILTER SCREEN MUST BE IN PLACE FOR WATER TO FLOW ITEM PART NUMBER DESCRIPTION 1 7003 095 001 VALVE ASSEMBLY 2 7000 060 000 FLOW REGULATOR CARTRIDGE 0 5 GPM 3 7003 097 001 O RING STRAINER PLUG 4 7003 864 000 STRAINER FILTER SCREEN 5 7003 194 199 VR MAINTENANCE TOOL 6 7003 197 199 VR PUSHBUTTON ESCUTCH...

Страница 6: ...kmfg com Member of ITEM PART NUMBER DESCRIPTION 1 7012 311 000 WF1 Filter 1500 Gal 2 1895 709 000 Elbow Push in 1 4 O D x 1 4 Stem 3 2169 000 000 1 4 O D LLDPE Tubing Blue 4 7012 055 000 Foam Pipe Insullation 5 7003 670 001 Filter Assembly FG FILTER MOUNTING DETAIL LINE TO DRINKING FOUNTAIN INLET INSTALLED FILTER DETAIL NOTES 1 CUT AND DEBURR WATER LINE TUBING AS REQUIRED 2 ENSURE TUBING END IS NO...

Страница 7: ...the cartridge turning clockwise to secure 5 Re insert the water filter into the water filter bracket assembly 6 Turn water inlet 1 4 turn knob 1 4 turn counterclockwise to open and test for leaks and proper operation before closing access panel I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T ...

Страница 8: ...in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N ...

Страница 9: ...RINKING FOUNTAINS A172FGVR Page 9 of 10 New 08 01 16 7020 930 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of COOLER PARTS BREAKDOWN Universal Maintenance Tool Button Removal Cartridge Retaining Nut Strainer Plug Removal of P E Tubing from Push in Fittings 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ...

Страница 10: ... Center Reject Allen Flat head Screw 6 7003 635 199 FG VR Hanger Bracket 7 7003 681 299 Access Plate VR Auto Stop 8 7000 006 000 Flat Drain Adapter Gasket 9 7000 005 199 Drain Adapter 10 7000 019 001 1 1 4 Tailpiece Assembly 11 7003 073 000 11 4 x 1 1 2 Compression 45 Elbow 12 1758 043 299 1 1 2 O D x 3 Long Drain Tube 13 7003 072 000 1 1 2 x 1 1 2 Compression 45 Elbow 14 1758 043 199 1 1 2 O D x ...

Отзывы: