background image

 

 

A152-VR-BF4

Page 17 of 20

Date: 

10/28/2020

7021-023-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

CARTRIDGE VALVE PARTS BREAKDOWN

3

2

1

5

4

1. Strainer Plug must be removed before Cartridge replacement and Strainer maintenance (no need to turn the 

water off at the Angle Stop). Some residual water will drainduring Plug removal.

2. Clean Strainer as needed using clean water.

3. Cartridge Replacement - insert diamond end of the Universal Tool into Pushbutton, rotate 90 degrees and pull 

firmly to remove the Button. Remove Cartridge Retaining Nut . Remove and replace Cartridge. When replacing 
Cartridge, be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body.

 NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.

 

CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE 

Note: Use the Universal Maintenance Tool to perform the following:

-Button Removal
-Cartridge Retaining Nut

-Removal of P.E. Tubing from

Universal Maintenance Tool

 Push-in Fittings

-Strainer Plug

6

ITEM #

PART NUMBER DESCRIPTION

1

7003-095-000

Valve Body Sub Assembly

2

7000-060-000

Valve Cartridge

3

7000-052-000

Retaining Nut

4

7003-864-000

Strainer, Auto Stop

5

7003-097-001

Strainer Cap

6

7003-194-199

Maintenance Tool

 

For Stainless steel units:

3. 

Periodically remove fountain top and clean out in-line strainer.

CLEANING & MAINTENANCE GUIDE:

For Powder coated units:

 Units should be cleaned using a mild soap solution with a sponge or cotton cloth. 

Wipe down surfaces then rinse with clean water.

2. 

Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it 

will cycle on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air 
hose or brush the condenser fins and cabinet ventilation louvers. In environments where dirt and dust is 
more prevalent, clean more frequently.

1. 

Motors have lifetime lubrication and do not require scheduled maintenance.

4. 

Periodically remove access panel of cooler and clean out inline “Y’’ strainer

1.    To Remove water spots or rust spots, stainless steel cleaner/polish on a cloth is  recommended.
2.    If there are stubborn spots or if you wish to treat a scratch, synthetic abrasive general  purpose pads   such as   

scotch brite are recommended.

3.    Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/polish is maintained, 

stainless steel surfaces will retain their new, clean, polished appearance indefinitely.

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Содержание A152-VR-BF4 Series

Страница 1: ...r implied Product maintenance instructions are issued with each unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain or Murdock s limited warranty is v...

Страница 2: ...allic taste or cause water metal content to increase NOTICE A152400S VR BF4 Wall Mounted Drinking Fountain NOTES Dimensions shown for Adult ADA compliant installation For Child ADA compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes A152 VR BF4 ...

Страница 3: ...s A152 VR BF4 Page 3 of 20 Date 10 28 2020 7021 023 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS General Notes 1 All dimensions are in inches 2 Dimensions shown are for recommended ad...

Страница 4: ... 1 General Notes 1 Dimension indicated with is for 33 drinking fountain discharge height if discharge height differs adjust accordingly 2 Standard Bi Level rough ins shown For RBL Reverse Bi Level RBL Mounting Frame rough ins opposite 1 1 4 O D Drinking Fountain Waste Outlet 3 8 NCT Drinking Fountain Supply Inlet Alternate 3 8 NCT Bottle Filler Supply Inlets Alternate 1 1 4 O D Bottle Filler Waste...

Страница 5: ...ide structure support around inside of the opening for frame anchoring B Carefully remove Bi Level Moutning Frame 1 and panel from packaging preventing damage C Center both frames within wall opening with side top and bottom lips overalpping outside the opening and up against finished wall face Secure to wall through the sides top and bottom using hardware 2 by others ensuring 16 centerline dimens...

Страница 6: ...g to 724 kPa 105 psig Murdock Mfg will not warranty chiller damaged when connected to supply lines with flow pressure lower that 174 kPa 25 psig or higher than 724 kPa 105 psig A pressure regulator must be furnished by others on supply line if inlet pressure is greater than 724 kPa 105 psig 4 Remove the drinking fountain top by taking out the drain screw and lifting at the front while pulling forw...

Страница 7: ...all the bottle filler panel using the water filler bracket and secure the bottle filler by tightening the screws under the bottle filler BOTTLE FILLER INSTALLATION 1 With drinking fountain installed connect water supply line from multi line Y strainer assembly to bottle filler DRINKING FOUNTAIN START UP 2 Air within the drinking fountain system or the structure supply piping will cause an irregula...

Страница 8: ...m Member of WATER TUBING CONNECTIONS NOTE Insulation on all water tubes not shown all PE water tubes are insulated CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS PE Tubing PE Tubing Fill Spout 9 12VDC Solenoid Valve Solenoid Valve Outlet Elbow w Flow Control Solenoid Valve Inlet Fitting 3 Way Divider Assembly Y Strainer ...

Страница 9: ...orner of Mounting Frame 1 2 3 4 5 In Out Connect 1 4 Tubings to Drinking Fountains and Bottle Filler Valve 7 6 WATER TUBING DIAGRAM ITEM PART NUMBER DESCRIPTION 1 0250 006 000 10 x 5 8 Phillips Truss Head Screw 2 7014 035 199 Water Filter Bracket 3 0124 031 000 8 x 3 8 Hex Washer Head Screw 4 1895 709 000 Elbow 1 4 Push In x 1 4 Stem 5 7012 311 000 WF1 Filter 1500 Gallon 6 2169 000 000 Tubing 1 4 ...

Страница 10: ...n clockwise to close OPTIONAL WF1 WATER FILTER INSTALLATION 4 Turn inlet 1 4 turn knob 1 4 turn counterclockwise to open and test for leaks and proper operation before installing bottom access panel back onto unit 3 Remove and replace the cartridge turning clockwise to secure 2 With the filter assembly secured on the unit hold the cap firmly turn the replaceable cartridge filter counterclockwise t...

Страница 11: ...ug in power is a standard feature 1A Plug In Operation Plug transformer provided into GFCI protected electrical service used by the semi recessed bottle filler Plug in transformer to power supply and connect to red sensor wire CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS Red Wire Blue Wire Sensor Plug In Transformer Junction Box ...

Страница 12: ...rs REPLACEMENT FILTER alert function Alert reset when filter is replaced Bottle Counting Function The software applies a flow volume of approximately 16 9 fl oz volume in standard size plastic water bottle to each bottle counted If the flow volume is less than 16 9 fl oz there will be no count but the volume will accumulate so that part way through the next cycle the total bottle count will change...

Страница 13: ... not the unit has a filter or does not have a filter The reset button will also take away the REPLACE FILTER alert once the filter has been replaced CLEARING REPLACE FILTER ALERT Systems With or Without Filter Depress the Reset Mode selection button for 6 Seconds the number of seconds will count up on the display At the end of the 6 seconds FLTR YES or FLTR NO WILL APPEAR on the display FLTR YES m...

Страница 14: ...rdockmfg com Member of OPTIONAL BCD BOTTLE COUNTER DISPLAY BOTTLE FILLER BOTTLE COUNTER CONNECTIONS Solenoid Connection Power Supply Connection Black Cables Sensor Connection Black Red Cables Sensor Connection Transformer Solenoid Valve Bottle Count Display Sensor CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS ...

Страница 15: ...G THE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should b...

Страница 16: ...warmer a Ensure water supply service stop valve is fully open a Cartridge The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow 2 RESTRICTED OR NO WATER FLOW b Verify minimum 20 psig supply line flow pressure d Check the water inlet Y strainer Sediment from the main supply can get trapped in the screen a...

Страница 17: ...000 Strainer Auto Stop 5 7003 097 001 Strainer Cap 6 7003 194 199 Maintenance Tool For Stainless steel units 3 Periodically remove fountain top and clean out in line strainer CLEANING MAINTENANCE GUIDE For Powder coated units Units should be cleaned using a mild soap solution with a sponge or cotton cloth Wipe down surfaces then rinse with clean water 2 Excess dirt or poor ventilation will cause t...

Страница 18: ...ter 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x 1 Hex Flat Head Screw 13 0124 055 000 8 x 3 4 Phillips Round Head Screw 6A 7000 012 001 ...

Страница 19: ... BF4 Page 19 of 20 Date 10 28 2020 7021 023 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS 31A 26 27 28 29 32 33 34 35 37 36 38 30 10 11 12 13 18 16 19 21 20 17 15 6 5 1 24 25 9 14 7 8 ...

Страница 20: ...0116 010 000 10 32 UNF x 1 2 S S Phillips Truss Head Screw 17 7013 238 199 3 Way Divider Clamp 1 4 18 7013 235 001 3 Way Divider Assembly 1 4 x 1 4 19 7013 237 002 3 Way Divider Bracket Assembly 1 4 x 1 4 20 0331 042 000 6 Helical S S Spring Lock Washer 21 0302 011 000 6 32 UNC Hex Finished Full S S Nut 22 7000 245 000 Back Panel Spacer 7014 062 199 Trim Panel Upper BL w Rectangular Fountains 7014...

Отзывы: