Prior to roughing in, consult with local, state, and federal codes for proper mounting height.
DIMENSIONAL DRAWING
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
A152.8-BF4
Page 5 of 23
Revised:
07/18/18
7020-949-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
ANCHORING CLIP DETAIL
4
6
3
30
1
4
"
50
1
2
"
16"
1
5
56
1
4
"
Anchoring Clip Detail
Notes:
1-Standard Bi-Level rough-ins shown. For -RBL Reverse Bi-Level, -RBL
Mounting Frame rough-ins opposite
2-Chiller installation is always on the right-hand side of the shelf
Installation Instructions:
A
-Provide 30-1/4" wide x 50-1/2" tall wall opening at
appropriate height. Provide structural support around
inside of the opening for frame anchoring.
B
-Carefully remove Bi-Level Mounting Frame 1 , chiller
mounting frame 2 , panel, anchoring clips 3 , and
screws 4 from packaging, preventing damage.
C
-Center both frames within wall opening with side, top
and bottom lips overlapping outside the opening and up
against finished wall face. Set chiller shelve in place,
aligning anchoring holes with holes in frame bottom.
secure to wall through the sides, top and bottom using
hardware 5 by others, ensuring 16" centerline
dimensions left-to-right.
D
-Install two anchoring clips 3 at bottom on outer sides
of chiller mounting frame 2 align holes in clips with
holes 6 in frame and use sheet metal screws 4
provided. See anchoring clip detail.