background image

A311.8 Series

Compact and Deluxe Wall Mounted Water Coolers

 

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

 

 

 

 

 

COMPLIES 

WITH

7020-919-001 

      

Date: 09/01/20

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

LIMITED EXPORT WARRANTY - 

One year on parts only. 

LIMITED WARRANTY - UNITED STATES & CANADA

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above.

A311108F-G / A311108S-G / A311108Q-G

A1311408F / A311408S / A311408Q

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 WATER COOLERS

 

Содержание A1311408F

Страница 1: ...ch unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain or Murdock s limited warranty is void LIMITED EXPORT WARRANTY One year on parts only LIMITED WA...

Страница 2: ...etallic coupler is furnished with this water cooler to meet this requirement A311 8 Page 2 of 9 Revised 09 01 20 7020 919 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of AIR FLOW GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 ALLOW 4 INCHES 102 MM MINIMUM CLEARANCE PER SIDE FOR VENTILATION 3 DIME...

Страница 3: ... 1 4 O D p trap waste connection Waste p trap by others START UP 4 Anchor the water coolers to the wall at the lower mounting points in each back panel Shim lower mounting points to level unit if necessary 6 Plug water cooler in to electrical outlet and make sure unit begins to function 5 With power still NOT connected carefully manually rotate cooling fan to insure proper clearance and free fan a...

Страница 4: ...densation 12 Per UPC 609 10 All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve These pressure absorbing devices shall be approved mechanical devices Water pressure absorbing devices will be installed as close as possible to the quick closing valve 2 Pr...

Страница 5: ...g condition in which the water will become frozen inside the evaporator coil This indicates a refrigeration problem or thermostat failure in which case the water cooler needs to be checked by a qualified technician 2 Compressor Does Not Run a Check the electrical receptacle for power and correct voltage The incoming voltage must be within 10 of the rated voltage on the serial nameplate b The cold ...

Страница 6: ...ess steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner CARTRIDGE VALVE PARTS BREAKDOWN STANDARD CARTRIDGE VALVE PARTS BREAKDOWN ITEM PART NUMBER DESCRIPTION 1 7000 050 001 Valve Cartridge Assembly 2 7000 060 000 Valve Cartridge 3 7000 053 199 Jam Nut ITEM PART NUMBER DESCRIPTION 1 2 3 7000 000 001 7000 060 001 0401 015...

Страница 7: ...e PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET C...

Страница 8: ... 15 28 27 18 28 27 18 NOTE Flow Restrictor Only Available With Low Flow Bubbler 29 A311 8 Page 8 of 9 Revised 09 01 20 7020 919 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS ...

Страница 9: ... 000 FAN MOTOR 7012 062 001 FAN MOTOR 220V 7005 506 020 SIDE PANEL GRAY 7005 511 199 SIDE PANEL STAINLESS STEEL 0124 056 000 8 x 3 8 LONG PHILLIP PH SHEET METAL SCREW 7003 250 000 COLD CONTROL 7003 120 001 EVAPORATOR ASSEMBLY 7004 407 199 BACK PLATE 7004 408 199 HANGER BRACKET 7000 021 001 Y STRAINER 7000 032 001 DRAIN TUBE ASSEMBLY 7000 005 199 DRAIN ADAPTER 7000 006 000 FLAT DRAIN ADAPTER GASKET...